Use as a dry vacuum cleaner
Attention! Only use the unit as a dry vacuum cleaner with the enclosed filter bag!
Ensure that the unit stands safely. Switch the unit off with the switch and pull the power plug. Unlock the container
locking system (A1), remove motor housing (A2). Pull the enclosed filter bag (C1) over the suction socket (C2) inside
the container (A3). Refit and lock motor housing. Connect the unit to the power supply and turn it on with the switch.
Select a suitable nozzle. At end of work, switch the unit off at the switch.

Maintenance and cleaning

Switch the unit off with the switch and pull the power plug. Remove all hoses and the motor housing. Thoroughly rinse
the collection container. Remove the foam filter (D1) and clean it with clear water. Check the foam filter and, if dama-
ged, replace it by an original OASE foam filter. Check sealing rings for damage and completeness. If necessary,
change the rubber seal in the drain valve. Only use original OASE filter bags.
Malfunctions
Trouble shooting
The unit does not perform its suction function
The unit does not reach its full capacity
The collection container does not drain, the unit
switches off immediately following the drain
pause
Low suction capacity

Wearing parts

Foam filters, valve rubber parts and filter bags are wearing parts and are, therefore, not covered by our warranty.
Storage
Storage
Empty out the collection container and clean the unit. Store in a dry, frost protected room, inaccessible to children.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Cause
Drain hose incorrectly fitted
Excessive height difference between water
level and unit
Dirt has accumulated in the foam filter, in the
suction tube or in the suction hose
Dirt has accumulated in the area of the non-
return valve at the drain hose preventing it from
closing properly
The collection container cannot drain
Collection container and drain hose are soiled
The more tubes are used, the higher the tube
frictional resistance. The suction capacity
reduces.
Remedy
The non-return valve must be located at the
free end of the drain hose
We recommend to place the unit at a height
identical to the water level
Remove dirt
Remove dirt
Lay the drain hose without kinks. Provide a
slight gravity for the drain hose. Once drained,
the container must be almost completely empty
Remove dirt
How to improve the suction capacity:
Hold the suction tube as flat as possible