2. Design and function
For model TR22-B resistance thermometer
EN
2) In the event of replacement, select a resistance thermometer measuring insert model TR11-A.
The corresponding sensor length, l
Insertion length U
DIN 11866 row A or metric
Nominal
Nominal
width of
pressure
pipe
in bar
OD
PN
10
25
15
25
20
25
25
25
32
25
25
40
50
25
65
16
80
16
100
12.5
3) Maximum operating temperature 150 °C
4) All thermowells of this series that are internally pressurised, with a nominal diameter (DN) > 25 mm, are
manufactured and tested to module H of the pressure equipment directive.
6
, is calculated as follows:
5
+ neck tube length M (85 mm) + 5 mm pre-load + 10 mm head dimension
1
Outer
diameter
of pipe
Ø D
3) 4)
13
19
23
29
35
41
53
70
85
104
Pipe
Pipe
schedule
length
s
TL
1.5
70
1.5
70
1.5
80
1.5
100
1.5
110
1.5
120
1.5
160
2.0
210
2.0
260
2.0
310
WIKA operating instructions thermowell, model TW61
Thermowell
Neck tube
insertion
length
length
TR21-B TR22-B
U
M
1
6
51
9
48
11
46
18
39
18
39
18
39
30
27
30
27
45
12
45
12
M
129
126
124
117
117
117
105
105
90
90