technical adjustments
GB
Correcting the room sensor
The detected room temperature may be
corrected.
Simultaneously press and hold the tem-
perature adjustment buttons "
"
for approximately 5 seconds.
The temperature value will fl ash on the
display.
Press the temperature adjustment but-
tons "
" to increase or decrease
the correction, from + 3 to - 3 °C.
Press the operating mode button to con-
fi rm the correction.
Press the operating mode button once
again to exit.
The display will visualise the detected
room temperature.
Zone allocation
Simultaneously press the adjustment
buttons "
" for approximately 5
seconds: the temperature reading will
fl ash on the display.
Press the operating mode button: the
temperature will appear on the display
in a fi xed manner for a few seconds, then
the number of the zone to be allocated
will fl ash on the display.
Press the adjustment buttons "
" to
select the number of the zone to be al-
located. Press the operating mode but-
ton to confi rm: the display will visualise
the zone number in a fi xed manner for
a few seconds, then the detected room
temperature will appear once again.
The device has now been allocated to the
selected zone.
It is advisable to perform an on/off inter-
vention on the bipolar switch outside the
boiler so that the modifi cation can take
effect.
19