Fig. 8
STEP 4. CONTROLLER ADJUSTMENTS
If adjustments are required. Note factory defaults for program shown in Quick Reference Chart.
Otherwise, replace the driver board housing cover as the electronic product is ready for use.
Symbol
Function
d
Sensor Range
Auto Timer
T
(faucet shut-off)
R
Rinse Cycle
r
Rinse Time
b
Buzzer
L
LED
M
Metering Mode
061209A
Mixed Water
Sensor Plate
Fig. 7
Hardwire
Connection
Hardwire Battery Clip
(Note: connection already
made to converter)
DRIVER BOARD QUICK REFERENCE CHART
Description
You can set the distance at which the sensor will detect hands
in the wash area.
A safety mode in the event the sensor continually sees a target.
If this feature is turned to an "xx" hour value, the faucet will turn
on itself after this set time from last use.
This is the amount of time you want the faucet to stay on to move
the water in the line, if the Rinse Cycle is made active.
Buzzer will annunciate twice upon power up indicating product is
ready to use.
LED will light up indicating low power.
This feature changes the product into a metering faucet; it will run
the full set amount of time after the user's hands are first detected.
57 mm (2.25")
MIN*
061264A
Spout Plate
Hardwire Converter
24VAC to 6VDC
061252A
Controller
w w w . s p e c s e l e c t . c o m
Page 3
061210A
Cold Water
Sensor Plate
060072A
Screws and
Driver Bit Kit
Sensor Lead
060683A
Controller Battery Clip
(Note: connection already
made to controller)
Solenoid
Leads
Factory
Function Settings
Default Setting
8" from sensor
3" to 15" from sensor
5, 7, 10, 12, 15, 30, 45, 60, 75, 90
45 seconds
seconds
2.0, 4.0, 6.0, 8.0, 9.9 minutes
- (OFF)
- (OFF), 6, 12, 18, 24, 30, 36,
42, 48 hours
10 seconds
10, 20, 30, 40, 50, 60, 90 seconds
(once enabled)
2.0, 2.5, 3.0 minutes
ON
ON, - (OFF)
ON, - (OFF)
- (OFF)
-- (OFF), 7, 8, 9, 10, 11, 12, 13,
10 seconds
14, 15, 18, 24, 30, 40, 50, 60, 90
seconds
2.0, 2.5, 3.0, 3.5, 4.0 minutes