Racking; Ventilation And Racking - Opus Technologies LD Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Nom du modèle | Manuel d'installation et d'utilisation | Installation and user manual |

4. Racking

4.1 Ventilation and racking

Leave a space of 1U (44mm) above the amplifier
Leave a space of at least 168 mm between the
bottom of the rack and the amplifier
Attention, avertissement, danger:
LD1 / 2 / 3.2 amplifiers contain an ad-
vanced protection circuit, which allows
them to reduce the power output to
maintain safe operating temperatures. Insufficient
ventilation may cause the amplifier output power to
be reduced during normal operation (indicated by
the red LIMITER / PROTECT LEDs lighting up). To re-
duce the risk of thermal limitation and allow proper
heat dissipation, it is recommended to keep clear
the space directly above and behind these ampli-
fiers.
4.2 Rack integration
4.2.1 Integration of a rack amplifier
Option required: OP-R mounting kit
Secure the rack mounting brackets as shown to
the right using the mounting screws provided in
the kit.
Then integrate the amplifier into the bay.
4.2.2 Integration of two rack amplifiers
Option required: OP-R mounting kit
Secure the rack mounting brackets as shown to
the right using the mounting screws provided in
the kit.
Then, attach the amplifiers to each other using
the brackets.
Finally, integrate the amplifiers into the rack.
26