Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Instructions
Features
• One 10/100/1000 RJ45 port supporting a maximum distance of 100 m (300 ft.)
• One 1000Base-LX fiber SC single-mode port supporting a maximum distance of 20 km (12.4 mi.)
• IP40 slim-type metal housing to withstand harsh industrial conditions
• Option for DIN-rail installation
• Two redundant DC inputs (12 - 58 V)
For specifications, visit intellinet-network.com. Register your product at
register.intellinet-network.com/r/508346 or scan the QR code on the cover.
Connections
Twisted Pair – RJ45
Connect the UTP port of the media converter to an
RJ45 port on the network (e.g., to an Ethernet switch).
Cat5e or better cabling is recommended.
Fiber Optic
As shown, two fiber optic cables need
to be connected between two ideally identical media converters. Make a connection from Media
Converter 1 TX to Media Converter 2 RX, and from Media Converter 1 RX to Media Converter 2
TX. Maximum length and fiber cable specification depend on the model. (See Models.)

Front panel

Item
LED
Port activity
RJ45 Port
Speed
Power and power-supply-
under-voltage alarm (priority
P — Power
of under-voltage alarm is
higher than power LED)
Fiber port and power
supply overvoltage alarm
O — Optical
(priority for overvoltage
Fiber Port
alarm is higher than fiber
port Link/Act LED)
Device alarm and data
A — Alarm
transmission indicator
Management indicator
N — NMC
and data receiving
2
English
TWISTED PAIR
Color
Status
Flashing
Sending or receiving data.
Green
On
Port is connected.
Off
Port is not connected.
On
1000 Mbps speed.
Yellow
Off
10/100 Mbps speed.
Flashing
Equipment power supply is lower than the lower limit of the input
every 1s
range of DC 12 V, indicating an under-voltage alarm.
Green
On
Power channel is powered.
Off
Power channel is not powered.
Flashing
The power supply of the device exceeds the upper limit of the
every 0.5s
input range of DC 58 V, indicating an overvoltage alarm.
On
Fiber port is connected.
Green
Off
Fiber port is not connected.
Flashing
Sending or receiving data.
Flashing
Console/RS232/RS485 port is sending data (LED flashes to the rhythm of data being sent).
Red
On
An issue has been detected (temperature, dying gasp, etc.).
Off
No alarm issue detected.
Console/RS232/RS485 port is receiving data (LED flashes
Flashing
to the rhythm of data being received).
Green
On
Module embedded and initialization is complete.
Off
No embedded module.
Example
MEDIA CONVERTER 1
TX
RX
RJ45
ETHERNET 1
OPTICAL FIBER
RJ45
TX
RX
Description
TWISTED PAIR
ETHERNET 2
MEDIA CONVERTER 2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Imci-smscg20km

Table des Matières