resideo AM-1 Serie Instructions D'installation page 2

Vannes de mélange et de répartition à débit proportionnel et modèle de plage de températures c
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AM-1 SERIES
WATER USE FIXTURES
(1)
T
PUMP
AM SERIES
M
TO DISHWASHER
IF PERMITTED
BY CODES
T
AQUASTAT
(1) CHECK VALVE
Fig. 1. AM-1 Series ASSE 1017 application. Dimensions
shown in in (mm).
Installation of Union Sweat, CPVC,
Union Propress, Push Connect and PEX
Connections
Union sweat connections, if used, should be soldered
prior to assembly to the valve, or without the sealing
gasket or optional check valve present. After the joint
has cooled, the sealing gasket and/or check valves
may be installed.
CPVC fittings are limited to a system maximum tem-
perature of 180° F (82° C) and 100 psi (689 kPa).
PEX fitting and crimp ring (provided by Installer) are
deigned to meet ASTM F1807 requirements.
PEX tubing used with PEX fittings must meet ASTM
F876 requirements.
Press connections, use press tools and installation
practices compatible with Viega systems.
Push connect fittings can be used with both copper
and LDPE (plastic). Utilize the included tube liners for
non-copper applications.
Installation of Temperature Gauge
Adapter
IMPORTANT
Union sweat connections must be soldered before
the thermowell with O-ring and sealing gasket are
installed. Install the thermowell with O-ring and
sealing gasket after the joint has cooled.
1. Install thermowell with O-ring to the thermometer
adapter body.
2. Tighten to 75 LB-IN ± 10 LB-IN. DO NOT OVER-
TIGHTEN.
3. Install the thermometer into the thermowell until
seated and tighten the set screw to secure in place.
62-3075EFS—11
RECIRCULATION
ALLOWABLE
SERVICE
(1)
VALVE
C
LOCATION
H
8
HEAT
(203)
COLD
TRAP
MAX
WATER
6
SUPPLY
(152)
V
WATER
HEATER
EXPANSION
TANK
M25029A
SCREW
Fig. 2. Temperature gauge installation.
VALVE ADJUSTMENT
To adjust temperature setting of the mixing valve, attach
thermostrip (supplied with the valve) to the piping connected
to the Mix port of the valve. Loosen handwheel screw, lift
handwheel and turn to desired temperature as indicated on
the thermostrip. Reposition the hand wheel and retighten
screw.
Temperature Setting Procedure
It is possible to limit the temperature range. To use this
feature:
1
2
c
1
LOOSEN SCREW, LIFT HAND WHEEL.
TURN HAND WHEEL CLOCKWISE
2
OR COUNTER CLOCKWISE TO
ADJUST TEMPERATURE.
2
THERMOMETER
THERMOWELL
O-RING
THERMOMETER
ADAPTER WITH
UNION NUT
GASKET
M36644
4
2
3
c
H
3
REPOSITION HAND WHEEL
TO LOCK POSITION.
4
RETIGHTEN SCREW.
3
H
M27487A