DIPSWITCH SETTINGS
STANDALONE MODE
Dipswitch
Description (SW7 OFF)
SW1
Used to determine the detector's sensitivity. Sensitivity is a function
SW2
of coverage area and surface material.
SW3
SW1 SW2 SW3
*OFF *OFF *OFF
ON
OFF ON
ON
OFF OFF ON
ON
OFF ON
ON
SW4
Used to detect single and extremely brief and intense signals
(including explosions and sledge hammers).
ON: Enable
*OFF: Disable
SW5
Used to adjust the integration time. In combination with SW1-3 they
SW6
establish a threshold value; SW5-6 establishes a cumulative alarm
signal value which, when exceeding the threshold value, triggers
an alarm event.
SW5
*OFF
ON
OFF
ON
SW7
Used to determine Stand Alone or BUS mode (Ensure that the J12
position (as below) matches the SW7 spec. )
ON: BUS
*OFF: Stand Alone
Used to determine Local or Remote Test
ON: Local. An internal self test is performed every 24 hours from
power-up. Test failure lights up the LEDs (see the Testing the
SW8
Detector section) and the LEDs remain lit until the next self test.
*OFF: Remote. A test is activated whenever the TEST input is
connected to GND. If the test passes, the alarm relay opens for
three seconds.
External test generator
SW9
ON: Enable External Test Generator
*OFF: Disable (internal test)
OFF OFF
OFF
ON
OFF
OFF ON
ON
ON
ON
SW6
Duration (in sec.)
*OFF 10 (example: vending machine)
OFF
26
ON
46
ON
80 (example: bank vault)
Seismic Detector
Low
Sensitivity
High
Sensitivity
EN
Low
Sensitivity
High
Sensitivity
9