Télécharger Imprimer la page

Publicité

Liens rapides

LuNAR
TM
360º CEILING MOUNT
DIGITAL PIR DETECTOR
Model: RK2000DPC
EN 50131-1 Grade 2, EN 50131-2-2, EN 50130-5 Class II
© RISCO Group 01/2022
ENGLISH
FIG. 1
PYROELECTRIC
CABLE
ELEMENT
KNOCKOUT
EOL Resistors
MOUNTING
KNOCKOUT
JP3
JP4
JP2 JP1
ANTI-TAMPER
DEVICE
TAMPER ALARM 12VDC
CABLE
KNOCKOUT
GENERAL DESCRIPTION
The LuNAR PR 360º ceiling mount digital PIR is designed with state-of-the-art
components to ensure reliable operation in a wide range of applications.
It has a wide 110º angle, 360º overview. LuNAR PR uses a dual element
pyroelectric technology and provides superior RFI/EMI protection.
In addition, the LuNAR PR has digital true temperature compensation.
INSTALLATION PROCEDURE
STEP 1
PRELIMINARY DECISIONS
Before installation you should study the space to be protected in order to
decide on the location of the LuNAR PR for best coverage. This unit is usually
designed to be installed above the center of the protected area.
The lens in LuNAR PR provides detection sectors (beams) arranged in three
all-round optical levels, the external including 12 sectors, the middle
12 sectors and the internal 6 sectors. This arrangement assures you the best
coverage of the area. See plan view, fig. 4.
PR
The unit should not be mounted in direct sunlight or any other direct light or any
heat source (i.e. above a stove, radiator etc.). Detection sectors should
be pointing towards the floor, not curtains, windows etc.
STEP 2
FRONTAL COVER REMOVAL
Hold the unit with its base in the palm of your hand
and turn the cover clockwise to open, as
illustrated in Fig. 2.
The turning movement will release the 4 latches
locking the cover to the base of the unit.
STEP 3
OPENING, MOUNTING AND CABLE HOLE
The unit includes knockouts for mounting and wiring. Open the appropriate
knockouts required the installation.
STEP 4
MOUNTING
Insert the cable through the hole you
opened and mount the bottom part
5IN1805 E
in its final location.
Seal the cable hole and any other
opening with a sealant (RTV or alike).
STEP 5
TERMINAL WIRING
The following wire connection should be made to the terminal strip located
at the right lower part of the PC board.
MOUNTING
KNOCKOUT
TERMINAL
(-) (+) 12 VDC
N.C.
TAMPER
NOTE: Ensure that cover is installed after mounting and wiring.
Do not check or test detector without cover closed.
STEP 6
WALK TEST
TERMINALS
Set the "PULSES" to "1" and "LED" to "ON" (JP1).
With the LuNAR PR closed and powered in the setting, the LED will light each
time detection occurs, so operation can be checked.
After walk testing, the LED setting may be SET to "OFF". Now the detector will
work normally, but the LED will not light when detection occurs and the intruder
will notice being detected.
STEP 7
SETTING THE PULSE COUNT
The number of pulses needed to activate the alarm can be set to "1", "2" or "3".
OPTICAL FEATURES
The following is a description of features of RISCO GROUP's Fresnel lens fitted
in LuNAR PR.
FIG. 2
To drill holes for
Marks for
mounting use the
mounting
4 marks on the back
side of the package.
DESCRIPTION
DC Voltage (9 to 16 VDC).
Normally closed alarm contacts.
Anti-tamper circuit.
FIG. 3
9'
2.75m
110º
13.4
27'
4.06m
8.23m
40'
12.2m
ISOMETRIC VIEW
FIG. 4
PLAN VIEW
FIG. 5
JP1 - LED ON / OFF
JP2 - PULSE COUNT
ON
OFF
3
1 2 3
1 2 3
1 2 3
FIG. 6
Schematic of EOL resisitors
JP3 -
ALARM EOL JUMPERS
NO
1K
TAMPER
2.2K
ALARM
4.7K
5.6K
TAMPER
ALARM
-12V+
6.8K
PANEL DEOL
Resisitor
(Factory settings)
SPECIFICATIONS
ELECTRICAL:
Detection technology:
Dual element PIR
Current consumption:
15 mA at 12 VDC
Supply voltage:
9-16 VDC regulated
Alarm contact:
24 VDC, 50 mA
Anti-tamper:
Normaly closed, 24 VDC,0.5 A
Pulse count:
Selectable 1-3
Temperature compensation: True Temp. compensation
RF immunity:
According to EN50130-4
Walk test:
1 LED
OPTICAL:
Lens:
Wide angle spherical Fresnel
Coverage:
110º angle, 360º overview
Detection Zones: 3 optical levels, 12 external sectors,
12 middle sectors, 6 internal sectors
Specifications are subject to change without prior notice.
SHOULD ANY QUESTIONS ARISE PLEASE CONTACT YOUR SUPPLIER.
2
1
1 2 3
1 2 3
JP4 -
TAMPER EOL JUMPERS
NO
1K
2.2K
4.7K
5.6K
6.8K
Resisitor
(Factory settings)
PHYSICAL:
Weight:
112 G (4 Oz)
Size:
Ø135 x 27 mm
ENVIROMMENTAL:
Operating
0ºC to 55ºC
temperature: (32ºF to 131ºF)
Storage
-20ºC to 60ºC
temperature: (-4ºF to 140ºF)