Operating manual
CONNECTING THE HOOVER
1 - Insert the duct into the hole 1.
2 - Connect the suction hose 2 and the power supply of the sander 3 (G1/4)
3 - Connect the coupler 4 to the hoover.
4 - Connect the unlubricated compressed air supply, not exceeding 10 bar.
5 - Select the «ON / AUTO» mode to activate the suction.
6 - The knob is used to adjust the operating pressure of the sander.
7 - The pressure gauge indicates the operating pressure of the sander.
FAILURES AND ANOMALIES
Failures
The hoover does not
work
The sander does not
work
CLEANING OF DUST DEPOSITS
At the end of the working day, check for dust deposits on the flat surfaces of the hoover (front, top, etc.). If there are
dust deposits, make sure that the metal clamp of the hoover is connected to the earth circuit of the installation and
carefully remove the dust deposits, avoiding creating explosive atmospheres.
Translation of the original
instructions
Check that the hoover is connected to the unlubricated
compressed air network.
Press the start button.
Check the pressure gauge inside the hoover.
It is set at the factory and should be at 3.5 bar.
Check that no hoses are pinched or disconnected.
Check that the bag or the duct is not blocked.
Check that the pneumatic hose is connected.
Check that the pressure gauge 1 indicates a pressure
of around 4 bar, otherwise adjust using the knob.
GYSDUST SELF EXTRACTOR
Anomalies
2&3
4
1
6
7
5