TROUBLESHOOTING
ORANGE LED flashes 1x.
E1
1
ORANGE LED flashes 2x.
E2
2
ORANGE LED flashes 4x.
E4
4
ORANGE LED flashes 5x.
E5
5
E8
ORANGE LED flashes 8x.
8
ORANGE LED is on.
RED LED flashes quickly
after an assissted set-up
RED LED illuminates
sporadically.
GREEN LED illuminates
sporadically.
The LED and the LCD
displays are off.
The reaction of the door
does not correspond
with the LED signal.
The LCD or remote
control does not react.
Page 7 of 9
The sensor signals an internal
fault.
The power supply voltage is
too low/high.
The sensor does not receive
enough AIR-energy.
The sensor receives too much
AIR-energy.
The sensor is distrubed by
external elements.
IR power emitter is faulty.
The sensor encounters a
memory problem.
The sensor sees the door
during assissted set-up.
The sensor vibrates.
The sensor sees the door.
The sensor is disturbed by
external conditions.
The sensor is disturbed by
rain and/or leaves.
Ghosting created by door
movement.
The sensor vibrates.
The sensor sees the door or
other moving objects.
No power to sensor.
Incorrect output
configuration / wiring.
The sensor is protected by a
password.
Replace sensor.
Check power supply voltage in diagnotistics menu
(menu 3) of the LCD.
Check wiring.
Decrease the angle of the AIR-curtains.
Increase the AIR-immunity filter.
Deactivate 1 curtain.
Slightly increase the angle of the AIR-curtains.
Decrease the AIR-immunity filter.
Eliminate the cause of disturbance (lamps, rain
cover, door controller housing properly grounded).
Replace sensor.
Cut and restore power supply.
If ORANGE LED illuminates again, replace the
sensor.
Move the AIR-curtains away from the door.
Install the sensor as close to the door as possible. If
needed, use a bracket assembly.
Ensure that the bottom of the sensor is mounted
within 2" of the bottom of the door header.
Launch a new assisted set-up.
Check if the sensor is fastened firmly.
Check position of cable and cover.
Adjust the IR angle and launch an assisted set-up.
Increase the AIR-immunity filter.
Increase radar-immunity filter.
Change radar filed angle.
Check if the sensor and door cover is fastened
firmly.
Check position of cable and cover.
Remove the objects if possible.
Change radar field size or angle.
Check wiring.
Check for correct power supply.
Check output configuration setting.
Check wiring.
Enter the correct password. If you forgot the
code, cut and restore the power supply to access
the sensor without entering a password during 1
minute.