2. CONTROLS (
2.2 O
M
PTIONAL
AIN
2.2.1 D
-T
ECO
OUCH
Resetting Maintenance Indicator: Press simultaneously on both arrow buttons,
Maintenance indicator will disappear from LCD screen.
After a power failure, the wall control returns to its original operation mode. All settings are kept in memory.
2.2.2 L
-T
C
ITE
OUCH
ONSTRUCTO
Activate the push-button. The color of the indicator shows the unit operating mode.
C
M
OLOR
ODE
G
I
REEN
NTERMITTENT
Y
M
.
ELLOW
IN
SPEED VENTILATION
R
M
.
ED
AX
SPEED VENTILATION
After a power failure, the Lite-Touch wall control settings will be erased.
2.2.3 C
ONSTRUCTO
Adjusting AIR SUPPLY CONTROL
1) Select speed "MIN" or "MAX" using slide switch (A).
• When "MIN" (minimum speed) is selected, if the knob (B) is set above
the click, the unit will exchange in low speed with the outside and if it
is set below the click, the unit will exchange on high speed with the
outside until the desired humidity level has been reached.
• When "MAX" (maximum speed) is selected, the unit will exchange on
high speed with the outside either if the knob is set below or above the
click.
2) To turn off the unit, slide the switch at the "OFF" position.
Adjusting DEHUMIDISTAT
Setting during summer months:
During this period, unless being afflicted with breathing problems, using the Dehumidistat is
unnecessary. Set the slide switch to "OFF" . (Do not exchange in day time; exchange at night time, if
cool outside, or if it is not raining.)
Setting during fall, winter and spring months:
(When severe condensation appears on windows.)
1) Determine the humidity level in your house (bring the knob (B) counterclockwise to its maximum
position, then bring it back clockwise slowly until you hear a "click").
2) Set the knob to one line under this temperature level or "click" .
Do not select a temperature below -20°C (-4°F). This could lead to excessive
dryness in the air causing discomfort for the occupants.
It is possible (and normal) to experience condensation on your windows when drastic
changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case, we
suggest waiting a few days to allow the situation to stabilize.
All manuals and user guides at all-guides.com
'
)
CONT
D
C
(
'
)
ONTROLS
CONT
D
P
F
OWER
S
UGGESTED USE
S
ELECT THIS MODE WHEN YOU ARE AWAY FROM THE
HOUSE FOR A FEW DAYS
THE INSIDE AIR IS TOO DRY IN HEATING SEASON
OR TOO HUMID IN COOLING SEASON
OFF
THE UNIT IS
VENTILATES
AT
MINIMUM
20
MINUTES OF THE HOUR
F
OR NORMAL DAILY OPERATION
F
OR EXCESS POLLUTANTS AND HUMIDITY
,
,
ODORS
SMOKE
ETC
CAUTION
9
AILURE
. A
,
LSO
WHEN YOU DEEM
. I
N THIS MODE
40
FOR
MINUTES PER HOUR AND
SPEED
THE
REMAINING
.
.
(
PARTIES
.).
AND
,
MAX
MIN
INTERMITTENT
,
L-T
,
VC0075
5°C
41°F
OFF MIN MAX
-
-5°C
23°F
-20°C
-4°F
B
A

CONSTRUCTO

VC0086