Setting the relative humidity level allows to select the maximum desired indoor humidity level (in
percentage). This value will be used to start the dehumidistat override (air exchange in high speed).
In the operating modes MIN, MAX and 20 min/h, the user can select a dehumidistat override so that
if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation
unit will exchange in high speed until the target indoor RH setting is reached.
An air exchanger is not a dehumidifier, but it can change the indoor relative humidity by bringing in
drier or more humid air from outside during non heating season. The dehumidistat override function
is useful to reduce indoor RH when the outdoor air is cool and dry during the heating season. Select
a target RH between 30% and 55% according to your comfort. When outdoor relative humidity is
high (e.g. in summer), turn off the override by pressing OK until the RH display disappears.
When the dehumidistat override is activated, the AUTO indicator will appear on
LCD scr e en to show that the actual mode is being overridden. Also, the relative
humidity appears (if it was not shown, see example at left). Once the target humidity
level is reached, the unit goes back into its original operating mode and AUTO
disappears from LCD screen.
NOTE: If the actual mode is MAX, only the relative humidity level appears on screen; AUTO label
will not appear.
To engage the dehumidistat override, press OK. The actual indoor RH and the %HUM label appear
on LCD screen.
NOTE: If the actual RH is less than 20%, then the humidity indicator will display "LO" , and if the
actual RH is greater than 80%, then the humidity indicator will display "HI" .
To turn off the dehumidistat override, press OK again. The RH and %HUM display will disappear
from LCD screen.
The maintenance indicator is represented by an M in a rounded
triangle, at the top of the house (see at right). If this indicator is
flashing, perform the regular maintenance (3 months), and if it is not
flashing, perform the annual maintenance (refer to Section 3).
All manuals and user guides at all-guides.com
'
)
CONT
D
C
(
'
ONTROLS
CONT
D
H
OW TO SET THE RELATIVE HUMIDITY
Press and hold OK for 3 sec. to access the settings menu. The
backlight will be activated during all the procedure.
The Relative humidity arrow and value will flash
(default setting: 45%).
OR
Use UP or DOWN arrow to change the value. The
value changes by 1% increments. Lower value:
30%. Upper value: 55%. Still flashing.
Press OK button to accept new value and quit settting menu.
D
O
EHUMIDISTAT
VERRIDE
M
AINTENANCE
)
(RH)
LEVEL
S
ELECTION
I
NDICATOR