PROBLEM
VACUUM WILL NOT OPE-
RATE
V ACUUM WILL NOT PICK-
UP OR SUCTION POWER IS
WEAK
DUST ESCAPING FROM V
ACUUM

TROUBLESHOOTING GUIDE

POSSIBLE REASON
No power in electrical outlet.
Dust cup container is full.
Dust cup filter needs cleaning
or replacement.
Dust cup container is full.
Dust cup filter is not installed
correctly.
Puncture/hole is dust.
POSSIBLE SOLUTION
Check fuse or breaker. Re-
place fuse/reset breaker.
Empty dust cup container.
Remove dust cup filter and
check for object(s) in air duct
and remove. Clean or replace
dust cup filter.
Charge unit.
Empty dust cup container.
Review dust cup filter instal-
lation instructions.