STA-RITE MAX-E-THERM SR400LP Instructions Pour L'installation
STA-RITE MAX-E-THERM SR400LP Instructions Pour L'installation

STA-RITE MAX-E-THERM SR400LP Instructions Pour L'installation

Masquer les pouces Voir aussi pour MAX-E-THERM SR400LP:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

MAX-E-THERM
GAS ORIFICE ADJUSTMENT KIT
NOTICE: See "Blower Identification Notice," Page 5
Failure to follow instructions could result in fire or explosion
with serious injury or property damage. This orifice replacement kit is to be
installed by a Sta-Rite distributor or other qualified agency in accordance
with the manufacturer's instructions and all codes and requirements of the
authority having jurisdiction. The qualified agency performing this work
assumes responsibility for this conversion.
The term "qualified agency" means any individual, firm, corporation or company which
either in person or through a representative is engaged in and is responsible for (a) the
installation or replacement of gas piping or (b) the connection, installation, repair, or ser-
vicing of equipment, who is experienced in such work, familiar with all precautions
required, and has complied with all the requirements of the authority having jurisdiction.
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
www.starite.com
Union City, TN • Delavan, WI • Mississauga, ON
© 2005, Sta-Rite Industries
TM
S E R V I C E
INSTALLATION INSTRUCTIONS
Kit No.
77707-2341
77707-2351
77707-2361
77707-2311
77707-2321
77707-2331
POOL HEATER
M A N U A L
for
Model No.
Model SR/SRC400LP
Model SR/SRC333LP
Model SR/SRC200LP
Model SR/SRC400NA, SR400HD
Model SR/SRC333NA
Model SR/SRC200NA
S417 (Rev. 11/30/05)

Publicité

Table des Matières
loading

Sommaire des Matières pour STA-RITE MAX-E-THERM SR400LP

  • Page 1 Failure to follow instructions could result in fire or explosion with serious injury or property damage. This orifice replacement kit is to be installed by a Sta-Rite distributor or other qualified agency in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction.
  • Page 2: Installation Instructions

    Installation Instructions Connection for NOTICE: The gas piping and Test Before proceeding with adjustment, verify that the kit unions have been omitted for contains all of the parts listed in the Repair Parts List clarity; make this test with all To High Side of Differential gas piping connected (as for...
  • Page 3 NOTICE: If neither correction above produces satisfactory 9. After the burner lights, verify that the supply pressure is combustion, consult your Sta-Rite distributor. The air/fuel within the range 4" to 14" wc. If the supply pressure drops ratio is adjusted by replacing the gas orifice with an orifice below this range when the burner ignites, the gas line of the correct size.
  • Page 4: Manifold Pressure

    6. Remove the gas orifice and O-Ring contained in the Table 3: Flue Gas CO and O Ranges union nearest the combination gas control valve (cor- Recommended Recommended rect union is next to sticker on gas pipe). 7. Install the O-Ring on the adjustment orifice (see Figure 4).
  • Page 5: Important

    MUST NOT are only used in the replace the orifices blower on the RIGHT. with the ones in this kit. Sta-Rite Pentair Gas and Air Orifices are not interchangeable between the two blower types. Risk of fire or explosion if this kit is incorrectly installed or is installed on the wrong unit.
  • Page 7 Cette trousse d’injecteurs de rechange doit être installée par un distributeur Sta-Rite ou une agence qualifiée conformément aux instructions du fabricant et à tous les codes et à toutes les conditions des autorités compétentes.
  • Page 8: Outils Requis

    Instructions d’installation Raccord d’essai REMARQUE : Pour plus de clarté, la Connection for NOTICE: The gas piping and conduite de gaz et les raccords-unions Test Avant de procéder au réglage, s’assurer que la trousse est la Du côté haute unions have been omitted for ont été...
  • Page 9: Réglage Du Rapport Air-Combustible

    Pour de plus amples renseignements, voir la Notice d’utilisation. au distributeur Sta-Rite. Le rapport air-combustible se règle en 10. Le brûleur étant allumé, débrancher le tube en plastique remplaçant l’injecteur de gaz par un injecteur de bon calibre.
  • Page 10: Pression D'arrivée

    6. Déposer l’injecteur de gaz et le joint torique du raccord union Tableau 3 : Gammes du CO et de l’O se trouvant le plus près de la soupape à gaz mixte (le bon des gaz de combustion raccord union se trouve juste à côté de l’autocollant apposé sur le tuyau de gaz).
  • Page 11: Identification De La Soufflante

    être remplacé par celui être utilisé qu’avec la livré avec la trousse. soufflante de DROITE. Sta-Rite Pentair Les injecteurs d’air et de gaz ne sont pas interchangeables entre les deux types de soufflantes. Il peut y avoir risque d’incendie ou d’explosion si cette trousse n’est pas posée correctement...

Table des Matières