Télécharger Imprimer la page

Axis M11 Serie Guide D'installation page 21

Masquer les pouces Voir aussi pour M11 Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to
factory default will reset all settings, including the IP address,
to the factory default values.
Note
The installation and management software tools are available
from the support pages on www.axis.com/techsup
To reset the product to the factory default settings:
1.
Disconnect power from the product.
2.
Press and hold the control button and reconnect power. See
Hardware Overview on page 10.
3.
Keep the control button pressed for 15–30 seconds until the
status LED indicator flashes amber.
4.
Release the control button. The process is complete when the
status LED indicator turns green. The product has been reset to
the factory default settings. If no DHCP server is available on
the network, the default IP address is
5.
Using the installation and management software tools, assign
an IP address, set the password, and access the video stream.
It is also possible to reset parameters to factory default via the web
interface. Go to Setup > System Options > Maintenance.
Further Information
The User Manual is available at www.axis.com
Visit www.axis.com/techsup to check if there is updated firmware available
for your network product. To see the currently installed firmware version,
go to Setup > About.
AXIS M11 Network Camera Series
21
192.168.0.90

Publicité

loading

Ce manuel est également adapté pour:

M1124M1125