Installation
Note on electrical system (see fig. b)
No. in fig. b
Description
1
Motor ventilator (inner)
2
Motor ventilator (outer)
3
Capacitor
4
Compressor
5
Temperature sensor
6
PCB
7
PCB Display
Only a qualified electrician should connect the under-bench air condi-
tioner to the electrical power.
Check that the voltage specification on the type plate is the same as that
of the power supply.
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
Install an all-pole switch with a contact opening width of at least 3 mm on
the installation side.
7.2
Making openings
See fig. 3
➤ Mark the position and size of the openings using the template included in
the packaging (A and B).
See fig. 4
➤ Drill out the corners (A).
➤ Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
Make sure no electrical power cables are damaged.
➤ Drill out a condensation water drainage opening with a diameter of
32 mm (C).
See fig. 5
➤ Mark the position of the angle sections (A) and the fastening brackets (B).
10
FreshWell2000
EN