eNet actionneur de commutation / à poussoir 8 voies / actionneur volet
roulant 4 voies, modulaire
Invert movement direction
Behaviour on voltage return
Configured venetian blind po-
sition
Configured slat position
Behaviour after the end of the
disabling function
Manual saving of the scene
values
Priority, lock-out protection
Activate lock-out protection
blind position
Activate lock-out protection
slat position
Deactivate lock-out protection
blind position
Deacitvate lock-out protection
slat position
82581933
J0082581933
On, Off
Basic setting: Off
No change
Configured value
Basic setting: No change
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
no change
Last value
Down
up
Basic setting: No change
On, Off
Basic setting: On
0...4
Basic setting: 1
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
17/20
Inverts the activation of the re-
lay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is re-
quired, for example, for
controlling skylights.
Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage re-
turn
If the value "Configured posi-
tion" is entered for the para-
meter "Behaviour after voltage
return", then the blind/shutter
position set here is approa-
ched.
If the value "Configured posi-
tion" is entered for the para-
meter "Behaviour after voltage
return", then the slat position
set here is approached.
Behaviour of the output when
a block is removed.
Disables the saving of the cur-
rent Venetian blind position as
scene value in an actuator for
a command via a transmitter.
Specifies the priority for recal-
ling and removing a scene of
type Lock-out protection for
the channel.
Defines the behaviour of the
output on activating the lock-
out protection.
Defines the slat position of the
output on activating the lock-
out protection. Only visible
when the Venetian blind ope-
rating mode is set.
Defines the behaviour of the
output on deactivating the
lock-out protection. Only vi-
sible when the priority for the
lock-out protection is 0.
Defines the behaviour of the
output on deactivating the
lock-out protection. Only vi-
sible when the priority for lock-
out protection is 0 and the Ve-
netian blind operating mode is
set.