FIXTURES WITH WALL WASH DISTRIBUTION ONLY (L*805*WW* Series)
The fixture is equipped with 4 reflector/refractor modules, each of them marked with an orientation arrow. To meet the specified light distribution, the
arrow needs to point up (ceiling) (Fig. 5). When in the right position, the arrow is located in the top right hand corner.
If the arrow points down (floor) re-orient the optics. Unscrew each of the 4 modules, rotate 180 degrees, locate the position by introducing the 2 location
legs in the matching holes of the LED board (Fig.6), re-install the screw.
Optics need to feel tight. Be careful not to scratch them and not to touch the LEDs with the screwdriver.
USE GLOVES in this process.
FIG. 5
ADAPTER