Technical data
Machine data
Shank
dimension
Type
CP 0122 S
H
(22 x 82.5)
CP 0122 SL
H
(22 x 82.5)
CP 0125 S
Rd. 1 x 3
(25 x 75)
Noise and vibration declaration statement
Guaranteed sound power level Lw according to EN ISO 3744 in accordance with directive 2000/14/EC.
Sound pressure level Lp according to EN ISO 11203.
Vibration value A and uncertainty B determined according to EN ISO 28927-10. See table "Noise and vibration
data" for the values of A, B, etc.
These declared values were obtained by laboratory type testing in accordance with the stated directive or
standards and are suitable for comparison with the declared values of other tools tested in accordance with
the same directive or standards. These declared values are not suitable for use in risk assessments and values
measured in individual work places may be higher. The actual exposure values and risk of harm experienced
by an individual user are unique and depend upon the way the user works, in what material the machine is
used, as well as upon the exposure time and the physical condition of the user, and the condition of the
machine.
We, Construction Tools PC AB, cannot be held liable for the consequences of using the declared values, instead
of values reflecting the actual exposure, in an individual risk assessment in a work place situation over which
we have no control.
This tool may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to
managing hand-arm vibration can be found at
http://www.humanvibration.com/humanvibration/EU/VIBGUIDE.html
We recommend a programme of health surveillance to detect early symptoms which may relate to vibration
exposure, so that management procedures can be modified to help prevent future impairment.
Noise and vibration data
Type
CP 0122 S
CP 0122 SL
CP 0125 S
18
Weight
in.
lb
(mm)
(kg)
7
x 3
1
25
8
4
(11.2)
7
x 3
1
28
8
4
(12.8)
28
(12.7)
Noise
Declared values
Sound pressure
EN ISO 11203
Lp
r=1m dB(A) rel
guaranteed dB(A) rel
20µPa
89
93
91
CP 0122 S, CP 0122 SL, CP 0125 S
Length
in.
Impact freq.
(mm)
22
1
4
(565)
22
(560)
24
4
5
(630)
Sound power
2000/14/EC
Lw
m/s
1pW
105
105
105
9800 0832 90e | Original instructions
Air Consumption
3
foot
/min
Hz
(l/s)
23
47
(22)
23
45
(21)
18
32
(15)
Vibration
Declared values
Three axes values
EN ISO 20643
A
B
2
2
value
m/s
spread
16.3
2.1
16.3
2.1
28.7
3.3