10. Remove, clean and reinstall the air 
filter  located  on  the  right  side  panel, 
then open the water tap  
 
 
NOTE. Once the cleaning operations are 
completed,  switch  on  the  equipment; 
the  ice  production  process  will  start 
after a delay of ten minutes. 
Make  sure  that  the  first  produced  ice 
doesn't  taste  slightly  acid;  in  any  case 
empty  the  bin  by  pressing  the 
dispensing  button  and  dispose  of  the 
ice  produced  during  the  first  10 
minutes.
 
 
 
 
 
 
 
 
 
12 
Six‐monthly maintenance  
 
After the equipment compressor  has 
been in operation for six months, the 
display will inform you that the water 
supply circuit of the machine needs to 
be cleaned, CLE will appear on display.    
The descaling of the Water Supply 
Circuit of the DXN Dispenser must be 
carried out by an authorised Scotsman 
service centre. 
Mechanical maintenance  
 
Mechanical maintenance is essential to 
ensure that the DXN Dispenser will run 
properly  for  a  long  time.  Contact  the 
authorised Scotsman service centre on 
a yearly basis. 
 
 
 
 
 
 
 