ELECTRICAL HEATERS 22-5215, -52151, -5230 & -52301
Specifications
Nominal voltage:
Nominal output:
Nominal current:
Flow and pressure:
Materials:
Outer tubes and heating element: AISI 316 stainless steel.
Tailpiece:
Union nut:
Water quality requirements:
Chloride:
Chlorine:
pH value:
Dimensions:
Length:
Max. height:
Storage temperature:
Operating temperature:
Overheating thermostat:
Regulating thermostat:
Important
Follow the directions for installation and connection. This heater is not suitable for medical use. We re-
serve the right to change the product and the specification without notice.
Safety rules
A.
Locate the heater in a dry area with good ventilation.
B.
The heater must be situated at least 3 cm above the ground floor.
C.
Before cleaning, servicing, exchanging of parts or accessories or checking up on various distur-
bances, the mains have to be cut off.
D.
Make sure that there are no unconnected wires and cables inside the box.
E.
Cables and wires must be as short as possible inside and outside the box.
F.
The heater is protection class I. It has to be connected with wires according to the instructions from
EN 60335-1 and EN 60335-2-60. It is recommended that you consult a state-registered electrician.
G.
Keep at all time minimum 20 mm distance between high and low power cables.
H.
In order to separate the heater from the mains you must install a suitable ground fault circuit inter-
rupter with at least 3 mm break distance on each terminal in the present electrical installation.
I.
The mounting is to be made in such a way that it is not possible to touch the electric parts. Install
the heater in such a manner that the user in the tub cannot touch any part of the heater or its ad-
justment appliances.
J.
The electric parts have to be mounted in such a way that they cannot fall into the bathtub.
K.
Instruments of class I must be connected to a permanent installation and safe guards must be es-
tablished by way of an equalizer connection to the existing water supply.
230V, 50-60 Hz
22-5215(1)
22-5230(1)
1,5 kW
3,0 kW
6.5A
13.0A
Min. 4.5 m ³ /h. Max. 23 m ³ /h @ Max. 3,0 atm.
PVC
ABS.
Max. 400 mg/l
Max. 2 mg/l
7.0-7.8
1.5kW: 280 mm. 3Kw: 345mm. (incl. tailpiece).
130 mm.
-20°C - + 60°C
Higher than 0°C.
Cutting-out at approx. 56°C. Manual operation
Approx 0°C - 40°C Only for product numbers ending with "1"
49-22-5215 –
www.hydroair.dk
– December 2009