ELECTRICAL HEATER 25-5260 & 25-52601
Specifications
Nominal voltage:
Nominal output:
Flow and pressure:
Materials
Outer tubes:
Heating element:
Tailpiece:
Union nut and box:
Water quality requirements
Chloride:
Chlorine:
pH value:
Dimensions
Length:
Max. height:
Storage temperature:
Operating temperature:
Overheating thermostat:
Regulating thermostat:
Important
Follow the directions for installation and connection. This heater is not suitable for medical use. We reserve
the right to change the product and the specification without notice.
Safety rules
A.
Install the water heater in a dry and well ventilated room.
B.
The water heater must always be placed at least 3 cm above floor level.
C.
Cut off the power supply prior to cleaning, repair work, replacement of parts or accessories,
and investigation of any irregularities.
D.
Make sure that there are no unconnected wires and cables inside the box.
E.
Cables and wires must be as short as possible inside and outside the water heater.
F.
The water heater is protection class I. It has to be connected with wires in accordance with
EN 60335-1 and EN 60335-2-60 instructions. It is recommended that you consult a registered
electrician. The water heater can only be firmly connected to fixed installation, and it has to be
ensured that it is supplied by a fault circuit breaker with a max. release current of 30 mA.
The installation must be done according to the general rules for power installations.
G.
Keep at all times minimum 20 mm distance between high and low power cables.
H.
The heater must be separated from the mains by a switch with a total distance of break of at
least 3 mm on each terminal.
I.
Install the water heater in such a manner that the user cannot touch live electrical parts.
Install the water heater in such a manner that the user in the tub cannot touch any part of the
water heater or its adjustment appliances.
J.
Install all electrical components in such a manner that they cannot drop into the tub.
K.
Devices of Class I shall be firmly connected to fixed installation, and protective measures shall be
taken in the form of an equalizing connection to existing water installation.
3 x 230V, 50-60 Hz
3 x 2kW
Min. 4.5 m ³ /h
Max. 23 m ³ /h@max. 3.0 atm.
AISI 316L
Incoloy 825
PVC
ABS
Max. 400 mg/l
Max. 2 mg/l
7.0-7.8
465 mm incl. tailpiece and box.
210 mm incl. tailpiece
-20°C - + 60°C
Higher than 0°C.
Cutting-out at approx. 56°C. Manual operation.
Approx. up to 42°C. Only for 25-52601.
49-25-5260 –
www.hydroair.dk
– March 2009