IMPORTANT INSTRUCTIONS -
Models:
LEDAK50, LEDAK80, LEDAK100,
LEDAK80H, LEDAK100H
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel
and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
210572203 Rev. AA 6/21
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
a) If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application and be connected to a GFCI (Ground Fault
Circuit Interrupter) – protected branch circuit.
b) Do not install in a ceiling with thermal insulation value greater than R40.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON
THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE
SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST
PERFORMANCE, AND AVOID INSTALLING THE FAN WITH SMALLER
DUCTS THAN RECOMMENDED. INSULATION AROUND THE DUCTS
CAN REDUCE ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS
INSTALLED WITH EXISTING DUCTS MAY NOT ACHIEVE THEIR
RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing LEDAK50

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: LEDAK50, LEDAK80, LEDAK100, Exhaust Fan with Light LEDAK80H, LEDAK100H READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 4" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL SECTION 1 BUILDING CODES.
  • Page 3: Standard Models

    Connect the Red wire from the fan to the load terminal of the switch. Use approved methods for all connections. Screw 3c. From where you have chosen to access the fan’s junction box, connect the White wire from the house to the two White wires from the fan. Connect the ground wire (green or bare copper) from the house to the Green wire from the fan (Figure 10).
  • Page 4 SECTION 8 Install the reflector onto the grill by placing the slots on the side of the reflector over the lens clips near the center of the grill. While squeezing the middle of the reflector, slide it so Use and Care that the plastic notches rest under the lens clips and the reflector feels secure (Figure 13).
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 6: Replacement Parts Diagram

    5S1202122 Collar Assembly 5S1299111 Wire Cover Assembly - LEDAK 5S1202660 Wire Cover Assembly - LEDAKH - Humidity Sensing 5S1202661 Blower Assembly - LEDAK50 5S2202029 Blower Assembly - LEDAK80/ LEDAK80H 5S2202401 Blower Assembly - LEDAK100/ LEDAK100H 5S2202401 LEDAK50 Motor Cap Harness...
  • Page 7: Instructions Importantes - Manuel D'opération

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: LEDAK50, LEDAK80, LEDAK100, Ventilateur combiner, comprend LEDAK80H, LEDAK100H lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION REMARQUE : UN CONDUIT PLUS RIGIDE DE 4 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9: Modèles Standards

    compartiment de câblage intérieur. Les deux méthodes sont également efficaces. la borne commune du commutateur. Connectez le fil noir du ventilateur à l’une des bornes commutées du commutateur. Cette position stimulera le mode automatique et le ventilateur 1a. Compartiment de Câblage Extérieur : enlever la vis du couvercle du compartiment à sera activé...
  • Page 10 SECTION 7 Installez la lampe incluse dans le support de lampe E26 (base à vis) (Figure 12). Réglage de l’humidostat Ce ventilateur peut être équipé d’un capteur d’humidité qui allume automatiquement le ventilateur, lorsque l’humidité est supérieure au point de consigne lorsque l’humidité est inférieure ou égale Socle au point de consigne.
  • Page 11: Guide De Dépannage

    Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché. 1b.
  • Page 12: Diagramme Des Pièces De Remplacement

    5S1299111 Assemblée du compartiment du fil - LEDAK 5S1202660 Assemblée du compartiment du fil - LEDAKH - Détection d’humidité 5S1202661 Assemblée de la Soufflante - LEDAK50 5S2202029 Assemblée de la Soufflante - LEDAK80/LEDAK80H 5S2202401 Assemblée de la Soufflante - LEDAK100/LEDAK100H...

Ce manuel est également adapté pour:

Ledak80Ledak100Ledak80hLedak100h

Table des Matières