Before using Clean&Renew™
Installing the cartridge
• Press the lift button (1) to open the housing.
• Hold the cartridge down on a flat, stable
surface (e.g. table). Carefully remove the lid
from the cartridge. Slide the cartridge into
the base as far as it will go.
• Slowly close the housing by pushing it
down until it locks.
Replacing the cartridge
After having pressed the lift button to open the
housing, wait for a few seconds before
removing the used cartridge.
Before discarding the used cartridge, make
sure to close the openings using the lid of the
new cartridge, since the used cartridge will
contain contaminated cleaning solution.
You may dispose of the used cartridge in the
normal household waste.
Operating your
Clean&Renew™
• Using the special cord set, connect your
Clean&Renew™ to an electrical outlet. The
special socket at the back is adjustable to
save space. After each shave, switch the
shaver off and put it into the
Clean&Renew™, upside down and with the
front showing.
• Push the start/release button (3) to lock and
connect the shaver. The cleaning process
will start. The yellow light on the shaver will
flash during the complete process (approx.
5 minutes cleaning, 4 hours drying).
• Do not interrupt the cleaning process, as it
leaves the shaver wet and not fit for use. If
interruption is needed nonetheless, press
the start/release button(3).
• When cleaning is finished, the yellow light
will go off and the shaver is ready for use.
To release it, push the start/release button.
10
A cleaning cartridge should be sufficient
for about 30 cleaning cycles. When the level
indicator (4) has reached the «min» mark,
the remaining fluid in the cartridge is
sufficient for about 5 more cleaning cycles.
After those 5 cycles, the cleaning perform-
ance will be reduced and the cartridge
should be replaced.
When used daily, the cleaning cartridge
should be replaced approx. every 4 weeks.
• The hygienic cleaning solution cartridge
contains alcohol which, once opened,
will naturally evaporate slowly into the
surrounding air. Each cartridge, if not
used daily should be replaced after approx.
8 weeks.
• Clean the housing from time to time with a
damp cloth, especially the opening where
the shaver rests.
Accessories
Available at your dealer or Braun Service
Centers:
Refill cartridge (double pack) CCR 2, (#5331)
Subject to change without notice.
Electric specifications see printing on the
special cord set.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

57225325

Table des Matières