Box Installation shown: (see Figure 3) — (sub-floor shown)
1. Cut opening in floor as shown for box.
2. Install box with temporary cover.
3. Secure box to floor using four #8 flat head screws
(not provided).
After Box installation: (see figure 5 and 6)
4. Remove and retain four #8-32 flat head screws [1] from top four corners of
the box.
5. Remove top mounting flange [2] with temporary cover [3] from box.
6. Turn two #10 screws [4] clockwise. Tighten screws until pawl arm is secured
to underside of floor. (see Figure 4)
7. Install conduits runs as required.
8. Re-install top mounting flange [2] with temporary cover [3]. (See figure 6,
Ensure that top mounting flange [2] align with notches [5] in box.)
CAUTION: Temporary covers are intended to keep debris from entering box
after installation and are not intended to support loads. Replace with perma-
nent flange/cover immediately after installation or temporarily reinstall metal
cover [3].
9. Consult electrical device mounting plate installation instructions for wiring
device installation.
10. Attach Flange with Cover (see figure 7).
Figure 5
PD2613
(Page 2)
05/15
PRINTED IN USA
Figure 3
11-1/4"
[28.6 cm]
11-1/8"
[28.3 cm]
Figure 4
3/4" floor shown
Pawl arm
Pawl arm adjustment for floor
thicknesses from 3/4'' [19.0 mm]
to 2.00" [51 mm] max.
Figure 6
3
2
1
4
5
Carpet Installation shown
Cut opening in carpet as shown for AFB Flange.
See Fig. A - For installation of AFB Flange with Cover detail.
#8 screws
AFB Flange for Carpet Installation – SURFACE (shown) - Open Cover and turn Jack Screws [4] to adjust AFB Flange
with Cover flush to surface of carpet.
Figure A
Carpet Flooring
Box
Floor Box
Depth
AFB4G25, xxCHI 2-1/2"
4GAFBCVRxx or 4GAFBCVRxxC
AFB4G50, xxCHI
5.0"
4GAFBCVRxx or 4GAFBCVRxxC
AFB Flange for Tile Installation – SURFACE (shown) - Open Cover and turn Jack Screws[4] to adjust AFB Flange with
Cover flush to surface of Tile.
Figure B
2
Access Flooring
Floor Box
Box
Depth
5
AFB4G25, xxCHI 2-1/2"
4GAFBCVRxx or 4GAFBCVRxxC
AFB4G50, xxCHI
5.0"
4GAFBCVRxx or 4GAFBCVRxxC
PD2613
(Page 3)
05/15
9.0"
[22,9 cm]
To attach Flange,
See Fig. 7.
Carpet
AFB Flange With Cover
Floor
Additionally: Apply
silicone compound.
AFB Flange With Cover
Tile
Mounting flange on box
PRINTED IN USA
Apply Silicone
compound to
flange.
Cover
Jack
Screws
Apply gasket
Jack
Screws