Install cooler/carbonator, see Figs. [1] and [5].
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order
to ensure that the cooling fluid has run back, the
cooler/carbonator may only be switched on following
a pause of 24 hours.
• A distance of at least 50mm must be maintained around the
cooler/carbonator at all times.
• Adequate ventilation must be ensured. If necessary, provide
ventilation grilles in the cover of the lower cabinet.
Install filter cartridge, see Figs. [6] to [9].
The filter head can be swivelled forwards by up to 90° in the
wall holder to install the cartridge.
The wall holder can also be fastened directly to the lower
cabinet or to the wall.
Connect cooler/carbonator, see Figs. [4] and [10] to [13].
Open hot and cold water supply and check that
connections are watertight.
Flush filter cartridge, see Fig. [14].
Press the flush button on the filter head in order to flush the
filter system. Continue flushing until the water emerging from
the hose is clear and free of bubbles (at least 2 litres).
Connect CO
cylinder, see Figs. [15] to [20].
2
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
The valve is only needed when cleaning the cooler/carbonator.
Connect plug-in connector of fitting to plug-in connector
of cooler/carbonator, see Fig. [21].
Establish voltage supply via mains plug, see Fig. [22].
The display illuminates and the remaining filter capacity is
displayed in percent.
Operation / commissioning
By turning handle, the carbon dioxide content of the cooled
and filtered water can be changed, see fold-out page III,
Fig. [23].
Control, see fold-out page III, Fig. [24].
The buttons have the following functions:
Filter replacement reset
Filter size selection
Carbonate hardness adjustment
Display, see fold-out page III, Fig. [24].
In the inactive state, the remaining filter capacity is displayed
in percent.
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see fold-out page III, Fig. [24].
Set carbonate hardness at filter head, see Fig. [25].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page IV.
5
will escape, see Fig. [16].
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page IV and
Fig. [24].
button for carbonate hardness adjustment:
• Press the
button once:
The display switches from the remaining filter capacity to the
value currently set for the carbonate hardness.
• Keep the
button pressed:
After approx. 3 seconds, the value currently set for the
carbonate hardness starts to flash.
• Release the
button within the next 10 seconds:
The value currently set for the carbonate hardness starts
to flash.
• Press the
button and select the required value:
- C1: carbonate hardness
- C2: carbonate hardness
- Factory setting:
C3: carbonate hardness
- C4: carbonate hardness
- C5: carbonate hardness
- C6: carbonate hardness
• Press and hold the
button at the required value
for 3 seconds:
The display of the value switches from flashing to
continuous illumination and the value is set.
• Release the
button:
The remaining filter capacity is displayed again:
The litre capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on
fold-out page IV.
The cooler/carbonator of the GROHE Blue
operation with the 600 litre filter cartridge (Prod no.: 40 404)
at the factory.
For operation with the 3,000 litre filter cartridge (Prod. no.: 40 412)
or 1,500 litre filter cartridge (Prod. no.: 40 430), the cooler/
carbonator must be adapted.
Set the filter size, see Fig. [24].
button for filter size selection:
• Press
button once.
The display switches from the remaining filter capacity to the
value currently set for the filter size.
• Keep the
button pressed:
After approx. 3 seconds, the value currently set for the filter
size starts to flash.
• Release the
button within the next 10 seconds:
The value currently set for the filter size starts to flash.
• Press the
button and select the filter size:
- F1:
600 litres
- F2:
1,500 litres
- F3:
3,000 litres
• Press and hold the
button at the required value
for 3 seconds:
The display of the value for the filter size switches from
flashing to continuous illumination and the filter size is set.
• Release the
button:
The remaining filter capacity is displayed again:
The fitting with cooler/carbonator is now fully installed and
ready for operation.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page III, Fig. [24].
button for filter replacement reset:
The remaining filter capacity is displayed:
• Press
button
The display switches from the remaining filter capacity to rF.
25 - 35
(bypass 20%)
18 - 24
(bypass 30%)
14 - 17
(bypass 40%)
12 - 13
(bypass 50%)
10 - 11
(bypass 60%)
7 - 9
(bypass 70%)
®
fitting is set for