ENGLISH
2
CiRCUlatOR
When started for the first time and at least once
a year, it is good practice to check the rotation of
the circulator shaft because, especially after long
periods of inactivity, deposits and/or residues may
cause it to become stuck.
The rotation of the circulator shaft can be checked
in the following way:
• Press on the icon
to access the main menu.
• Press the icon
on the display to access the
settings menu.
The submenus are password-protected
and are reserved to the service centre.
The user can access the installer menu
only to use the "Start pump" function.
It is forbidden to access the other
menus and change the parameters as
this could compromise the operation of
the appliance.
Settings
Installer menu
Service menu
Screen lock
Language
Info
• Press ON: the password appears, set 54 and
press OK to confirm.
Password
20
OK
• Press "Start pump".
Installer menu
Configurations
Room thermostat
Start secondary feeder
Start pump
Hopper unit
Press and hold the "Feed" button and check
that the circulator shaft is rotating correctly.
Start pump
Feed
The submenus are password-protected
and arnce..
If the circulator does not rotate and is stuck, it is
necessary to release it manually:
• protect the electrical devices below any water
leakage
• remove the circulator cap
• insert a screwdriver in the hole
• press and turn the screwdriver until the drive
shaft is released.
004778282 - 18/03/2022