Primary And Hepa Fi Lter Disassembly And Replacement; Primary Fi Lter Replacement - American Sanders CAV 50 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAV 50 - CAV 100
Primary and HEPA fi lter disassembly and
replacement
When the vacuum cleaner is used to vacuum
hazardous substances, the fi lters become
contaminated, therefore:
Work with care and avoid spilling the vacuumed
dust and/or material;
Place the disassembled and/or replaced fi lter in a
sealed plastic bag;
Close the bag hermetically;
Dispose of the fi lter in accordance with the laws
in force.
Filter replacement is a serious matter. The fi lter must
be replaced with one of identical characteristics,
fi ltering surface and category.
Otherwise the vacuum cleaner will not operate
correctly.
Primary fi lter replacement
1.
Vacuuming unit
2.
Locking lever
3.
Filter cage
4.
Primary fi lter
5.
Filter shaker housing
6.
Dracon fi lter
7.
Manual fi lter shaker knob
Take care not to raise dust when this operation is
carried out. Wear a mask and other protective clothing
plus protective gloves suited to the hazardous nature
of the dust collected, refer to the laws in force.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
US
Use lever (
2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
Remove the fi lters cage from the vacuum cleaner.
Remove the old fi lters by removing the plastic ties.
Fit the new fi lter and secure it in the cage with new
plastic ties.
Fit the new Dacron fi lter to the star fi lter and secure it
with new plastic ties.
Dispose of the old fi lters according to the laws in force.
C346
WARNING!
WARNING!
Figure 14/15
WARNING!
Replacing a primary fi lter with automatic fi lter
shaker
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
After replacing the fi lter in the cage (
container again.
Reassemble vacuum unit (
fi ts into shaped housing (5) of the fi lter shaker.
Turn the power switch on and the vacuum unit will self-
centre automatically.
Use locking lever (
2) to lock the vacuum unit in place.
Replacing a primary fi lter with manual fi lter shaker
1.
Vacuuming unit
2.
Locking lever
3.
Filter cage
4.
Primary fi lter
5.
Filter shaker housing
6.
Dracon fi lter
7.
Manual fi lter shaker knob
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
After having replaced and fi tted the fi lters in the cage,
insert fi lter shaker cage (3) in the shaped seat (5) of the
fi lter shaker.
Position the manual fi lter shaker knob (
Reassemble vacuum unit (
fi lter, in the vacuum container.
Check the fi lter shaker works properly and if necessary
adjust the position of the fi lter cage by turning the
vacuum unit, and turn down the edge of the Dacron fi lter
onto the fi lter chamber.
Use locking lever (
2) to lock the vacuum unit in place.
If necessary contact the manufacturer's Service Centre.
10
WARNING!
3), install it in the
1) making sure fi lter cage (3)
Figure 15
WARNING!
7) in the middle.
1) complete with cage and
04/2010

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cav 100

Table des Matières