Cooktop Burners - GE J2S968 Instructions D'installation

Masquer les pouces Voir aussi pour J2S968:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

COOKTOP BURNERS

24
ASSEMBLING THE BURNERS
A
CAUTION:
spark igniter is exposed. Be careful not to
snag the electrode of the spark igniter with
a cleaning cloth. Damage to the igniter could
occur. Be careful not to turn on any cooktop
controls while cleaning. A slight electrical
shock might result, which could cause you
to knock over hot cookware.
FOR GLASS CERAMIC COOKTOPS
a. Place the burner head on the burner base,
so that the pins match up with the slots on
the base.
b. Position the burner cap on the burner head.
c. Place the burner grate over the burner
assembly. The grates fit over the raised
area on the burner head.
Burner
grate
Burner
cap
Burner
head
Burner
base
Installation Instructions
The electrode of the
Spark
igniter
location
Spark
igniter
Glass
maintop
CHECK FOR LEAKS
B
Turn the gas supply on and use a liquid leak
detector (soap solution) at all joints and
connections to check for leaks. Do not use an
open flame to look for leaks. Be sure all leaks
are stopped before lighting burners.
PRESSURE TEST INFORMATION
C
The maximum allowable supply pressure
for the regulator is 14" W.C. The minimum
supply pressure needed to check the regulator
setting is 7" W.C. for natural gas and 10" W.C.
for LP gas.
WARNING:
individual shut-off valve must be disconnected
from the gas supply piping system during any
pressure testing of the gas supply system at
test pressures of more than 1/2 psig (pounds
per square inch gauge). The range must be
isolated from the gas supply piping system
by closing its individual shut-off valve during
any pressure testing of the gas supply system
at test pressures equal to or greater than
1/2 psig. NOTE: 1/2 psig = 13.855" w.c.