Code: 02250135- - 849 SR- - 5 --- SR- - 100
All figures to which the "see Fig." references in this text refer can be found at the
end this manual. The language translations for these figures can be found in the
Legend (A3--- sized page) inserted after all the figures.

1 Introduction

1.1

Foreword

The SR dryers are designed to guarantee high quality compressed air and minimum
maintenance.
Please carefully read this manual to obtain maximum performance from your dryer
and ensure its correct installation and start---up in compliance with manufacturer in-
structions.
1.2

Packaging

The dryer is packaged with a strong cardboard box strapped to a wooden pallet.
Instruction symbols (UNI ISO 780) for the movement, transport and stocking of the
product are printed on two sides of the packing.
THIS WAY UP
FRAGILE: HANDLE
KEEP DRY
DO NOT ROLL
USE NO HOOKS
WITH CARE
Kg max
STACKING
LIMITATION
1.3

Transport

S Keep the unit in an upright position and do not leave it outdoors.
S Use a forklift truck to move the machine.
S Care should be taken to avoid damaging internal components through poor han-
dling during movement, installation or use.
S Unpack the machine as close as possible to the installation site.
1.4

Storage

If stored the packaged units must be kept inside, protected from humidity, direct
sunlight and rain.
Moreover, although stacking is permitted the maximum weight must not be more
than the value shown on the packaging.
1.5

Inspection

On receipt of the machine, make sure it has incurred no damage during transit.
If any damage is detected promptly contact the haulage company.

2 Installation

2.1
Dryer installation (see Fig. 1)
a) Dryer should be installed indoors; where this is not possible it must however be
installed in a clean dry area, with a temperature within the limits 41---122˚F
(5---50˚C), and sheltered from the effects of direct weather (including direct sun-
light); do not install the dryer in rooms used for laundry operations.
b) The compressed air inlet temperature must never exceed 140˚F (60˚C). For dif-
ferent temperatures to those indicated above, consult the manufacturer.
c) For most compressed air applications we recommend following the installation
plan (see Fig. 1). This layout ensures optimum compressor, filter and dryer per-
formance and also guarantees excellent air quality whilst minimising operating
costs.
d) Do not obstruct the dryer air grilles.
e) Allow sufficient gap around the unit to facilitate maintenance and ensure unim-
peded air discharge from the condenser.
2
2
English