HAYWARD SELF-PRIMING SUPER PUMP
INSTALLATION AND OPERATING INSTRUCTIONS
Your Hayward self-priming centrifugal pump has been quality built and engineered to
is such that operation and maintenance has been reduced to simple, common-sense
procedures.
GENERAL TIPS ON PUMP INSTALLATION
Locate the pump as close to the pool as practical and run
suction line as direct as possible. This cuts down on
Never overtighten pipe connections — use only pipe
Tape, Permatex No. 2, etc. Suction line should have
continuous slope from lowest point in line. Make sure
suction joints are tight.
Suction pipe should be as large or larger than discharge
pipe.
Damp, non-ventilated locations should be avoided.
Motors require free circulation of air to aid in cooling.
Insure electrical supply agrees with motor voltage,
phase and cycle, and that wire size is adequate for the
HP/KW rating and distance from power source. Motor
must always be properly grounded. Electrical circuits
should be protected by proper size ground fault circuit
interrupter. Electrical wiring should be performed by
and regulations.
MAINTENANCE
Clean strainer basket regularly. Do not strike basket to
1.
clean. Inspect strainer cover gasket regularly and
replace as necessary.
2.
Hayward pumps have self-lubricating motor bearings
and shaft seals. No lubrication is necessary.
3.
Keep motor clean. Insure air vents are free from
obstruction.
4.
Occasionally, shaft seals become damaged or worn
and must be replaced. See instructions.
HAYWARD POOL PRODUCTS CANADA, INC.
® Hayward Pool Products Canada, Inc. — Licensee
2880 Plymouth Drive, Oakville, ON L6H 5R4 1-888-238-7665
Haywardpool.ca
STARTING AND PRIMING INSTRUCTIONS
Fill strainer/housing with water to suction pipe level.
Never operate the pump without water. Water
acts as a coolant and lubricant for the mechanical shaft
seal.
Open all suction and discharge valves, as well as air
displaced from the suction line must have someplace to
go.)
Turn on power and allow a reasonable time for priming.
Five minutes is not unreasonable. (Priming time
depends on suction lift and horizontal length of suction
piping). If pump will not start, or will not prime, see
TROUBLE SHOOTING GUIDE on back page.
WINTERIZING/STORAGE
1.
Drain pump by removing drain plug(s) and store in
strainer basket.
2.
Disconnect electrical wires and pipe connections,
and store pump in a dry, well-ventilated room. Or, as a
minimum precaution: Disconnect electrical wires.
Remove four bolts holding bracket and motor
assembly to Strainer/ Housing and store assembly in
a dry, well-ventilated room. Protect remaining
Strainer/Housing assembly from the elements by
covering.
NOTE: Before Re-Activating pump, thoroughly clean and
remove scale, dirt, etc.
IS2600XLHC-19

Publicité

Table des Matières
loading

Sommaire des Matières pour Hayward EXPERT Serie

  • Page 1 IS2600XLHC-19 HAYWARD SELF-PRIMING SUPER PUMP INSTALLATION AND OPERATING INSTRUCTIONS Your Hayward self-priming centrifugal pump has been quality built and engineered to is such that operation and maintenance has been reduced to simple, common-sense procedures. GENERAL TIPS ON PUMP INSTALLATION STARTING AND PRIMING INSTRUCTIONS Locate the pump as close to the pool as practical and run Fill strainer/housing with water to suction pipe level.
  • Page 2 PART NUMBER RE F. MODEL MODEL MODEL MODEL MODEL MODEL DESCRIPTION REQ’D SP2605X7 SP2610X15 SP2621X25 SP2600X5 SP2607X10 SP2615X20 1&2 Hand Knob & Swivel Nut SPX1600PN SPX1600PN SPX1600PN SPX1600PN SPX1600PN SPX1600PN Strainer Cover SPX1600D SPX1600D SPX1600D SPX1600D SPX1600D SPX1600D Strainer Cover Gasket SPX1600S SPX1600S SPX1600S...
  • Page 3 SEAL CHANGE INSTRUCTIONS SP2600 SERIES GENERAL Exercise extreme care in handling and installing the new seal and seat assembly. The lapped and polished surfaces may easily be damaged by dirt or scratching. For safety, all service must be performed with REMOVING THE MOTOR ASSEMBLY SEAL INSTALLATION Remove the (4) 3/8"...
  • Page 4: Troubleshooting Guide

    SERVICE AND REPAIRS Consult your local authorized Hayward dealer or service center. No pumps or motors may be returned directly to the factory without the express written authorization of Hayward Pool Products Canada, Inc.
  • Page 5 IS2600XLHCF-19 POMPE AUTO-AMORÇANTE HAYWARD SUPER PUMP INSTRUCTIONS POUR L'INSTALLATION ET LE FONCTIONNEMENT Votre pompe centrifuge auto-amorçante Hayward de qualité a été conçue et fabriquée avec soin et son entretien. CONSEILS GÉNÉRAUX SUR L'INSTALLATION Les circuits électriques doivent être portégés au moyen d'un disjoncteur-detecteur de fuite à...
  • Page 6 NUMÉRO DE PIÈCE MODÉLE MODÉLE MODÉLE MODÉLE MODÉLE MODÉLE Nombre N° de DÉSIGNATION SP2605X7 SP2610X15 SP2621X25 SP2600X5 SP2607X10 SP2615X20 réf. requis 1&2 Bouton manuel et écrou rotatif SPX1600PN SPX1600PN SPX1600PN SPX1600PN SPX1600PN SPX1600PN SPX1600D SPX1600D SPX1600D SPX1600D SPX1600D SPX1600D Couvercle de la crépine SPX1600S SPX1600S SPX1600S...
  • Page 7: Instructions Pour Le Changement Des Joints Étanches

    INSTRUCTIONS POUR LE CHANGEMENT DES JOINTS ÉTANCHES SÉRIE SP2600 RENSEIGNEMENTS GÉNÉRAUX Faire preuve d'une grande prudence au moment de manipuler et d'installer le nouvel ensemble de joint étanche et de siège. Les surfaces chevauchées et polies peuvent facilement être endommagées par la saleté...
  • Page 8: Guide De Dépannage

    ENTRETIEN ET RÉPARATION Consulter votre dépositaire ou centre d'entretien Hayward autorisé régional. Aucune pompe ni aucun moteur ne doivent être retournés directement à l'usine sans le consentement préalable par écrit de Produits de Piscines Hayward Canada, Inc. Haywardpiscine.ca...

Ce manuel est également adapté pour:

Sp2600 serieSp2600x5Sp2605x7Sp2607x10Sp2610x15Sp2615x20 ... Afficher tout

Table des Matières