MOUNT PLATE FOR "GLACIER II" PLOW FRAME
KIT PN 2879116
MOUNT PLATE INSTALLATION
INSTRUCTIONS
1.
Remove the two machine screws retaining the lower
part of the existing front bumper to frame.
2.
Unscrew a few turns the two machine screws (one
on each side) retaining the upper part of the existing
front bumper to frame.
3.
Rotate the existing bumper up to facilitate the
installation of the mount plate .
4. Position and fasten the mount plate bracket  to
frame using
(2) M10-1.5 X 50 mm
flange nylock nuts o.
(2) M10-1.5
5.
Reposition the existing front bumper in place. Take
care to align the lower mounting holes.
7515260
A-7515260
6. Fasten the upper part of the mount plate  to mount
7. Fasten the lower part of the mount plate  to frame
RIGHT
FRONT VIEW
carriage bolts h and
LIMIT SWITCH ASSEMBLY
INSTRUCTIONS
1. To remove the lower cover of the limit switch d,
FRONT VIEW
- 2-
plate bracket  installed in step 4 using
hex bolts i and
X 30 mm
(finger tighten at this time).
using
hex bolts i,
(2) M10-1.5 X 30 mm
washers m, and
(2) M10-1.5
Secure all bolts and nuts.
insert the end of a flat screwdriver in the opening
and turn as illustrated.
(4) M10-1.5
flat washers m
(4) M10
flat
(2) M10
flange nylock nuts o.
RIGHT
FRONT VIEW