FIGURA 1 – CAUDAL
INSTALACIÓN
Instale la válvula con la entrada de agua caliente (indicada con una H) conectada a la salida del agua
caliente de la caldera, la entrada de agua fría adyacente (indicada con una C) conectada al retorno de la
caldera y la entrada de agua fría situada en el lado opuesto (indicada con una C) conectada al retorno del
colector. La salida del agua de mezcla directamente aguas arriba a la bomba.
FIGURA 2 – DIAGRAMA DE INSTALACIÓN
ORKLI, S.Coop.
Ctra. Zaldibia, s/n, E – 20240 Ordizia (Gipuzkoa) ESPAÑA
Tel. : +34 943 80 94 80
cal@orkli.es
ES
E-19813
Fax : +34 943 80 52 41
www.orkli.com
TEMPERATURE ADJUSTMENT
•
Prior to setting the valve, it is necessary for the hot water source to be switched on and delivering hot
water at normal operating temperature.
•
Test the mixed water temperature at the nearest outlet being supplied by the valve.
•
Allow the water to run for at least one minute to ensure the mixed water temperature has settled.
•
The valve has two modes of temperature adjustment:
c)
Adjustable to a preset maximum and
d)
Locked temperature operation
a) Adjustable (with preset maximum)
•
Remove the securing screw.
•
If adjusting knob is currently in the locked
position, remove the adjusting knob and
replace it in a new position that allows it
to rotate freely.
•
Set the outlet temperature to the maximum
required temperature.
•
Replace the adjusting knob with the 'lock'
label to the right of the locking tab but not
in the locked position. This represents the
maximum position of the knob. From this
point the temperature can be adjusted
lower, but not higher. Tho adjust lower,
turn the adjusting knob clockwise. If it is
possible to turn the knob anticlockwise (ie
to a higher temperature) then step 3 needs
ORKLI, S.Coop.
Ctra. Zaldibia, s/n, E – 20240 Ordizia (Gipuzkoa) - ESPAÑA
Tel. : +34 943 80 94 80
cal@orkli.es
Installation Instructions
E-19813
to be repeated to set the knob in the
correct position.
•
Replace the securing screw.
•
If desired, use adjusting knob to set the
temperature lower than the maximum.
b) Locked temperature
•
Remove the securing screw.
•
If adjusting knob is currently in the locked
position, remove the adjusting knob and
replace it in a new position that allows it
to rotate freely.
•
Set the outlet temperature as desired.
•
Reposition the adjusting knob so that the
locking ring tab and the adjusting knob are
engaged.
•
Replace the securing screw.