ASSEMBLY INSTRUCTIONS
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
DO NOT obstruct the flow of combustion air and ventilation air to the fire pit.
The propane cylinder must be arranged for vapor withdrawal and equipped with a listed overfilling
prevention device. Please use the proper cylinder orientation to provide vapor withdrawal.
NOTE: The cylinder must be fully upright for the cylinder to have vapor withdrawal only.
Vapor
Liquid
CORRECT
a. Do not store a spare LP-gas cylinder under or near this appliance.
b. Never fill the cylinder beyond 80 percent full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or serious injury
may occur.
The pressure regulator and hose assembly supplied with the appliance must be used. The installation
must conform with local codes, or in the absence of local codes, with national fuel gas code, ANSI
A223.1/NFPA54, natural gas and propane Installation Code, CSA B149.1, or propane storage and
handling code, B149.2.
14. Put the gas cylinder into the gas housing of
the fire pit. Use the gas cylinder belt
(F) to fasten the gas cylinder in place. Before
connection, be sure that there is no
debris caught in the outlet of the gas cylinder,
inlet of the regulator valve or in the outlet of the
burner and burner ports. Ensure the propane
cylinder valve is turned off.
Then connect the propane cylinder to the
regulator (Q) as shown in figure 14.
Vapor
Liquid
WRONG
CAUTION
14
15
Vapor
Liquid
WRONG
Q
F

Publicité