Connect one phase conductor (normally brown or black)
•
8
to terminal "L" of the terminal block.
Connect the neutral conductor (normally blue) to terminal
•
"N" of the terminal block.
Connect the light system phase conductor of the lighting
•
system to terminal " L " of the terminal block.
Connect the neutral conductor of the lighting system to
•
terminal "N" of the terminal block.
Connect both the earth (ground) conductor (green/yellow)
•
of the light system and that of the power cable to the ter-
minal having the earth (ground) symbol.
Configuring the lighting system:
1. Testing Mode
To obtain the test position, turn switch TIME to "T" (Test)
•
and the switch METER to "+".
When movement is detected in the monitored area, the 4
•
LEDs and the lamp light for about 2 sec.
2. Settings
Setting the time
Use the TIME potentiometer to set the follow-up time (how
long the light stays lit following the last movement detected).
The range is variable from 6 sec. on the "-" position and 10
min. on the "+" position. Potentiometer turned to its max.
counter-clockwise position is the Test position, potentiometer
turned to its max. clockwise position is a pulse function (1
sec.).
Twilight setting
Use the LUX potentiometer to set the operating threshold of
the Motion Sensor between 5 and ∞ lux. Set the potentiome-
ter to its maximum counter clockwise position " " until twi-
light occurs. This ensures the detector remains inactive during
daylight. When twilight comes, set the desired lux level.
Sensitivity setting
The METER setting allows setting the detector sensitivity as a
function of the distance to the moving object. Turning the po-
23