PROBLEM
Main Burner Will Not Light
Low Burner Flame
Burner Unit
All manuals and user guides at all-guides.com
PROBABLE CAUSE
Gas valve may be OFF
Fuel tank empty
Air in supply system
Loose connection
Ignitor fails
Gas pressure low with valve open full
New cylinder or 1st time ignition
Pressure is low
Tank is low on fuel
Gas hose is kinked
Control knob at max
Thick black smoke

TROUBLESHOOTING - 13

Turn the gas valve ON
Clean or replace orifice
Purge air from lines. Open gas lines &
press control knob in for 2-3 min.
Replace battery or use match to light
burner
Replace cylinder or regulator
Purge air from lines
Replace hose/regulator assembly
Replace cylinder tank
Fill LPG tank
Check & straighten or replace
Check for obstruction at passageways or
Clean components as needed
Blockage in burner head unit
Thoroughly clean burner
** IMPORTANT NOTICE***
Do NOT return to place of purchase!!!
Please contact our Toll Free Hotline: 1-800-561-5550
for customer service and warranty issues
e-mail: parts@jrhome.com
Hotline hours: Mon. to Fri. 7:00am - 5:00pm ( P.S.T.)
SOLUTION