1. EXCITATION
2. BEFORE ITS USE
1. Use an independent electric source to prevent electronic disturbances.
2. Don't place any object on the platform when switching on the indicator.
3. Please, warm-up the scale during 2-3 minutes before using it.
4. Avoid sudden changes in temperature and draughts.
5. Don't overload the scale; do not exceed its maximum capacity.
3. CONSUMPTION
TC15
4. LOAD CELL CONNECTION TO THE INDICATOR
• The connector of the load cell has 7 pins.
• Do not disconnect the connector of the load cell when the indicator is working, because you could damage the equipment.
26
TC15
Input 230~240V
Output 10V 600mA
Rechargeable Battery
Battery life:
without backlight, approx. 160 hours.
With backlight, approx. 90 hours.
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
precision
Sensitivity Cell
Internal Resolution
selectable division
100~240V
12V 1000mA
6V/4Ah
EXC +
SEN +
SIG +
SIG -
SEN -
EXC -
N
Class III
1.5 ~3.0 mV/V