Excitation; Before Its Use; Consumption; Load Cell Connection To The Indicator - Baxtran BR 15 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. EXCITATION

2. BEFORE ITS USE

1. Use an independent electric source to prevent electronic disturbances.
2. Don't place any object on the platform when switching on the indicator.
3. Please, warm-up the scale during 2-3 minutes before using it.
4. Avoid sudden changes in temperature and draughts.
5. Don't overload the scale; do not exceed its maximum capacity.

3. CONSUMPTION

BR15

4. LOAD CELL CONNECTION TO THE INDICATOR

The connector of the load cell has 7 pins
• Do not disconnect the connector of the load cell when the indicator is working, because you could damage the equipment.
BR15
Input
230~240V
Output
10V 600mA
Rechargeable Battery
6V/4Ah
Battery life:
without back illumination, approx, 160 hours.
With back illumination, approx, 120 hours.
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
RS232 CONNEXION
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
EXC +
SEN +
SIG +
SIG -
SEN -
EXC -
GND
NC
RX
TX
NC
GND
NC
NC
NC
NC
USER'S MANUAL BR15
EN
39

Publicité

Table des Matières
loading

Table des Matières