Setting
Flow l/h between 0,1 and 0,6 bar
P 1
P 2
BP2
20
25
Adjustment principle of Kv
The adjustment of the desired flow should be using the embedded tool that displays the 12 adjustment
positions. Turn the tool with a screwdriver as shown in the diagram below. Place the number corresponding to
the desired flow in front of the indicator located on the hat.
Nominal level setting
Nominal level setting
• Close the valve completely and mark it with one position.
• Open and count 6 marks. The valve is now open at nominal opening.
• To install thermostatic head, remove the plastic cap.
• Put the thermostatic head in position 5, firmly push the head on the faucet and screw in hand tight.
P 3
P 4
P 5
30
60
90
We reserve the right to change designs and technical specifications of our products.
P 6
120
3