How to Charge the Battery Pack
Align the battery pack with the bay and slide the
battery pack into the charger as far as possible.
The red light will come on, either flashing quickly
(battery pack is too hot or cold), flashing slowly
(battery pack is waiting for another pack to finish
charging) or continuous (pack is charging).
• A fully discharged battery pack with an internal
temperature in the normal range will charge in
about 30 to 75 minutes, depending on the battery
pack.
• The Fuel Gauge lights on 18V battery packs are
displayed as the pack is being charged, indicating
how fully charged the pack is. The fuel gauge will
turn off when charging is complete.
• After charging is complete, the continuous green
light will come on.
• The charger will keep the battery pack fully
charged if it is left on the charger.
• The second pack inserted in the charger will be-
gin charging when the first pack inserted is fully
charged.
• If the light indicator flashes red and green, check
that the battery pack is fully seated into the bay.
Remove the battery pack and reinsert. If the light
continues to flash red and green, remove pack(s)
and unplug charger for at least 2 minutes. After 2
minutes, plug charger back in and insert pack. If
the problem persists, contact an ALBION service
facility.
• If the light indicator does not come on, check
that the battery pack is fully seated into the bay.
Remove the battery pack and reinsert. If the light
indicator still does not come on, remove pack(s)
and unplug charger for at least 2 minutes. After
2 minutes, plug charger back in and insert pack.
If after these attempts the light indicator still does
not come on, contact an ALBION service facility.
Charging a Hot or Cold Battery Pack
The Red Flashing Indicator light on the charger
indicates that the battery pack temperature is out-
side the charging range. Once the battery pack is
within the acceptable range, normal charging will
take place and the red light will be continuous. Hot
or cold batteries may take longer to charge.
Li-Ion Charging Status
Battery Pack
Red Charger
Temperature
Indicator Light
Too Hot
Fast Flashing
Normal Range
Continuous
Too Cold
Fast Flashing
Powering the Charger with an Inverter or
Generator
The charger will operate with most generators and
inverters rated at 300 Watts or higher.
Maintenance and Storage
Store your charger in a cool, dry place.
As a general practice, it is best to unplug battery
chargers and remove battery packs when not in
use. No battery pack damage will occur, however,
if the charger and battery pack are left plugged in.
All manuals and user guides at all-guides.com
Charging Status
Not charging
Normal charging
Not charging
WARNING
always unplug the charger and remove the
battery from the charger before performing
any maintenance. Never disassemble the bat-
tery or charger. Contact a an ALBION service
facility for ALL repairs.
To reduce the risk of injury and damage, nev-
er immerse your battery or charger in liquid or
allow a liquid to flow inside them.
Cleaning
Clean out dust and debris from charger vents and
electrical contacts by blowing with compressed air.
Use only mild soap and a damp cloth to clean the
battery pack and charger, keeping away from all elec-
trical contacts. Certain cleaning agents and solvents
are harmful to plastics and other insulated parts.
Some of these include gasoline, turpentine, lacquer
thinner, paint thinner, chlorinated cleaning solvents,
ammonia and household detergents containing am-
monia. Never use flammable or combustible solvents
around battery packs, charger, or tools.
Repairs
The charger has no serviceable parts.
LIMITED WARRANTY
This ALBION product is warranted to be free from
defects in material and workmanship. ALBION will
repair or replace any product which examination
proves to be defective in material or workmanship.
Limitations: This warranty does not cover: 1) repairs
made or attempted by other than ALBION Engineer-
ing or ALBION Engineering Authorized Service Sta-
tion personnel; 2) normal wear and tear; 3) abuse;
4) misuse; 5) improper maintenance; 6) continued
use after partial failure; 7) tools that have been modi-
fied; or product used with an improper accessory.
Battery Packs are warranted for one (1) year from
the date of purchase.
Should a problem develop, return the complete
product to any ALBION Engineering Factory Ser-
vice Center or ALBION Engineering Authorized
Service Station, freight prepaid and insured. If
inspection shows the problem is caused by a defect
in material or workmanship, all repairs or a replace-
ment will be made at no charge and the product
will be returned, transportation prepaid. No other
warranty, written or verbal, is authorized.
THE REPAIR AND REPLACEMENT REMEDIES
DESCRIBED HEREIN ARE EXCLUSIVE. IN NO
EVENT SHALL ALBION BE LIABLE FOR ANY
INCIDENTAL, SPECIAL, OR CONSEQUENTIAL
DAMAGES, INCLUDING LOSS OF PROFITS.
THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED
WHETHER FOR MERCHANTABILITY OR FIT-
NESS FOR PARTICULAR USE OR PURPOSE.
This warranty gives you specific legal rights.
You may also have other rights that vary from
state to state. In those states that do not allow the
exclusion of implied warranties or limitations of
incidental or consequential damages, the above
limitations or exclusions may not apply to you.
5
To reduce the risk of injury,