T60P Series Maintenance
Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
Replace seats and springs–Repair
Kit RP4993. Check condition of lower O-rings
and replace if necessary RP14414. See
Helpful Hints 1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074.
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant
water temperature:
Replace valve cartridge RP46074 or follow
instructions in Helpful Hints 1, 2, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly
for any maintenance, be sure to note the
position of the rotational limit stop on the cap.
The valve cartridge assembly must always be
put back in the same position. BE SAFE! After
you have finished the installation, turn on
valve to make sure COLD WATER FLOWS
FIRST.
2. To remove valve cartridge from body, shut
off water supplies and remove handle and
bonnet nut. Do not pry the valve cartridge
out of the body with a screwdriver. Place
handle on stem and rotate counterclockwise
Cleaning and Care
Care should be given to the cleaning
of this product. Although its finish is
extremely durable, it can be damaged by
approximately 1/4 turn after the stop has
been contacted. Lift valve cartridge out of
body.
3. To remove seats and springs, remove
valve cartridge. Separate cap assembly
from the housing assembly by rotating
the cap assembly counterclockwise 90
(degrees). Separate cap and housing
assemblies. Remove seats and springs and
replace. Place the largest diameter of the
spring into the seat pocket first and then
press the tapered end of the seal over the
spring. Reassemble valve cartridge and
replace in body following instructions given
in 1 above.
4. If the water in your area has lime, rust,
sand or other contaminants in it, your
pressure balance valve will require periodic
inspection. The frequency of the inspection
will depend on the amount of contaminants
in the water. To inspect valve cartridge
remove it and follow the steps in note 1
above. Turn the valve to the full mix position
and shake the cartridge vigorously. If there
is a rattling sound, the unit is functional and
can be reinstalled following instructions
given in note 1 above. If there is no rattle,
replace valve cartridge RP46074.
5. Make sure the rotational limit stop is fully
seated and retained. Use disc, if included.
harsh abrasives or polish. To clean, simply
wipe gently with a damp cloth and blot dry
with a soft towel.