Brizo MultiChoice T60P Serie Manuel D'installation page 10

Masquer les pouces Voir aussi pour MultiChoice T60P Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Siderna
Valve Trim Installation (T60P080)
®
A.
1
Remove plaster guard (1) from
rough (2).
Note: Depending on the location
of the valve in the wall and wall
thickness, an optional extension
kit (RP92056) can provide an
additional 1 3/4" of wall thickness.
C.
10
9
9
Assemble the two mounting sleeves (9) and
two mounting plates (10). Slide the mounting
plate assemblies over the trim sleeve so
that the tabs/plates (10) are at the top and
bottom of the trim sleeve, as shown. Thread
screws (11) into mounting plates just enough
to assemble the two sides together. Slide the
mounting plates back against the wall and
finish tightening the screws (11).
2
11
10
11
B.
7
7
Using supplied Hex wrench, install both anti-
rotational pins (3) into holes (4) in the valve body.
USE CARE TO NOT DROP PINS BEHIND THE
WALL. It is important that the rough be mounted
in the wall as level as possible because of the
square shape of this product. Slide trim sleeve
(5) over the cartridge and bonnet aligning the two
legs (6) of the sleeve over the anti-rotational pins
(3). If the trim is not square, you can try removing
a pin and holding the sleeve secure with the two
set screws (7) provided. Make sure the sleeve is
pushed all the way back so the legs of the sleeve
rest against the valve body. The set screws (7)
should be in a position where they hit just behind
the bonnet nut (8). Tighten set screws (7).
D.
Using the mounting plates (10) as a guide,
enlarge hole around rough so that plates can
be pushed up to 1/8" into the wall. Tighten
screws (11).
8
3
8
6
5
4
3
10
11
1/8"
(3 mm)
11
10
109507 Rev. A
4

Publicité

Table des Matières
loading