ELECTRIC CONNECTION 220 VAC
The metering must be linked with a power supply voltage
(Protected) of 230 VAC - 50 Hz - 5 VA minimum
by device presenting a distance of opening of the contacts
of at least 3 mm between every pole.
If the power cable is damaged,
it must be replaced by the manufacturer, his after-sales service
or a person of similar qualification to avoid any danger.
IN CASE OF CHANGE OF the POWER CABLE,
IT IS IMPERATIVE TO:
Cut the power supply (230 VAC) before any intervention
of the operator. Replace the cable by an equivalent.
Unsheathe this cable on a maximum 12 mm length.
Strip every driver on a 4 mm length.
Tin just the extremity, screws have to tighten the not tinned stalks.
Hand a clamp collar of the cable near the border of connecting
and an other one near the gland.
ELECTRIC CONNECTION 24 VAC
Cut the power supply voltage.
Remove the cable fixed to the border 230 VAC.
Possibly, use this cable for the food(supply) 24 VAC.
It is imperative to remove both STRAPS inside the metering, then to connect the border 24VAC of the metering
with the power supply voltage through a cable (type HO5VVF) 2 X 0.75 mm² minimum.
ADJUSTEMENT
.
2 4 v
N°377 MASTERDOSE R 220V 24V
T H U M B W H E E L
O F R E G U L A T IO N
M IN I
M A X I
RINSING
Make the regulations desired by means of the potentiometer,
spotted "DEBIT" according to the capacity of the dishwasher
knowing that the flow of the pump rinsing is adjustable 0.02 ml/h
to 1020 ml/h.
Position
0
1
Ml / minute
1
2.5
2 4 v
S U P P L Y IN G
C A B L E
2
3
4
5
4.6
6.6
8
10
EDITION 26/06/2013
S T R A P S
6
17