If some AD044 outputs are not used, the linked output in the
ATS control panel must not be programmed (default).
Refer also to the ATS1290 manual for the direct link to the
zone number (control panel).
Memory location map
Every PID device has its own characteristics concerning
related I/O lines or certain functionality of the device.
A total of 16 memory locations are reserved to configure
the PID devices. Only the first nine are normally user
configurable. This depends on the functionality of the particular
device.
For the AD044 external PID interface only memory locations 3
and 5 matter.
On memory location 3, the zone type can be configured for
each input to single EOL, double EOL (default) or the zone can
be switched off (the status will always be "Normal").
On memory location 5, the output supervision can be enabled
(default) or disabled for each output.
Memory location map for AD044
Location
Function
Decimal values
3
Zone types
For example:
0 = All zones are
Off
85 = All zones are
single EOL
170 = All zones
are double EOL
(default)
5
Supervision
For Example:
outputs
0 = All output
supervisions
disabled
15 = All output
supervisions
enabled (default)
Zone type
Input loop
Status ATS control
resistance
panel
Double EOL
<20 Ω
Short
47 kΩ
Normal
94 kΩ
Alarm
> 1 MΩ
Open
Specifications
Bus protocol
Bus voltage
External power supply
Current consumption from bus
Unit load for DGP
Address range
Maximum current outputs
P/N 1051425 (ML) • REV C • ISS 24JAN13
Binary values
Zone 4: Bit 7–6
Zone 3: Bit 5–4
Zone 2: Bit 3–2
Zone 1: Bit 1–0
00 = Zone is Off
01 = Single EOL
10 = Double EOL
(default)
11 = Undefined
Output 4: Bit 3
Output 3: Bit 2
Output 2: Bit 1
Output 1: Bit 0
0 = Disabled
1 = Enabled (default)
Status ATS control
panel
Single EOL
Short
Normal
Open
Open
Point ID
12 or 24 V
12/24 V [1]
290 A
1
0 to 255
500 mA (each)
Single EOL resistor inputs
Double EOL resistors inputs
EOL resistors Outputs
Category
Device type
[1]
The auxiliary power output of closest panel or DGP can also be
used.
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance with
the essential requirements and other relevant
provisions of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.