Installation Guide
6: Adding room devices
8
Danfoss Link™ CC - Configuration
All devices must be configured, according to the previous plan for the installation, to ensure the signal path.
Remove the front cover and press the Set-Up pin for 3 seconds.
1. Select Rooms and Devices.
4. Select Room devices.
7. Press Enter.
Note! Danfoss Link™ automatically selects the regulation principle according to the types of devices in
the room. To change regulation principle, see page 10.
VISGL45X
© Danfoss
2. Select Manage Existing Room.
5. Select Add a device.
When the first unit in relation to CC device is added, a link test must
be performed in order to ensured a successfully communication - see
manual for the individual device how this is done - but be sure that
CC is located on final destination before test is carried out.
Subsequently, the other repeaters must be added, before all remain-
ing devices are being added.
When you have completed adding all devices for the individual room,
an overview of devices associated to the room will be showed.
Press back symbol to get to the Room Devices menu, where all as-
sociated room devices are listed.
04/2011
3. Select a room..
6. Select Begin Registration.