repeated for 5 times, and then the fixture will generate a reset signal, all the stepper
reset.
If the fixture remain error message after performing reset more than 3 times, it will
detect
whether the fixture has more than 3 errors. If the fixture has more than 3 errors
(including
3 errors), all the channels cannot work properly; but if the fixture has less than
3 errors,
only the channels which have errors cannot work properly, others can work as usual.
Troubleshooting :
Following are a few common problems that may occur during operation. Here are some
suggestions for easy troubleshooting:
A.The fixture does not work, no light
o Check the connection of power and main fuse.
o Measure the mains voltage on the main connector.
No response to the sound
o Make sure the fixture does not receive DMX signal.
o Check microphone to see if it is good by tapping the microphone.
Fixture Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning
frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the fixture's
optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days