TROUBLE SOLVING

PROBLEMS
Air leaking near the top of the tool or in
the trigger area.
Air leaking near the bottom of the tool
Tool dose nothing or operates sluggishly 1. Inadequate air supply.
Fasteners are jammed in the tool
frequently.

POSSIBLE CAUSES

1. Loose screws.
2. Worn or damaged O-rings or seals. 2. Install overhaul kit.
1. Loose screws.
2. Worn or damaged O-rings or seals. 2. Install overhaul kit.
2. Tool is too dry.
3. Exhaust blocked.
4. Worn or damaged O-rings or seals. 4. Install overhaul kit.
1. Driver channel is worn.
2. Piston is broken or worn.
3. Bent fasteners.
4. Dirty magazine.
5. Loose magazine.
6. Wrong fasteners
9 - ENG LISH
SUGGESTED SOLUTIONS
1. Tighten screws.
1. Tighten screws.
1. Make sure the air compressor is set
between 70PSI and 115PSI.
2. Add about 2-3 drops of lubrication
into the air connector.
3. Clean exhaust channel.
1. Fix the drive channel.
2. Replace the piston.
3. Remove the bent fasteners, replace
with the right fasteners.
4. Clean magazine.
5. Tighten screws.
6. Verify that fasteners are the correct
size.