INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious
injury or death. Only qualified electricians should install this fixture and the installa
Electrical Code Part I and all local codes and ordinances. Ensure that only proper tools, materials, and equipment are used to
complete the installa
n.
SAFETY
Proper grounding is required to ensure personal safety.
Servicing this equipment should be performed by qualified service personnel.
Save these instru ons.
INSTALLATION
1. Loosen phillips head screw(s) which secure heatsink to base. Remove heatsink from base hinge.
for proper alignment. Apply silicone caulk all around mounted base to preclude water intrusion.
5. Reassemble heatsink to base hinge and close fixture tightly. Secure phillips head screw(s) accordingly.
Phillips Head Screw(s)
FIG1
WIRING
Make sure that the mains voltage is appropriate and conforms with the
luminaire driver.
Connect fixture GROUND (green) wire to power supply GROUND (green) wire.
Connect fixture WHITE wire to power supply (-) COMMON wire.
Connect fixture BLACK wire to power supply (+)LINE wire.
© 2017 Philips Lighting Holding B.V. All rights reserved.
www.philips.com/luminaires
Page 1 of 2
READ, UNDERSTAND, and FOLLOW these instructions
before installing the equipment.
A-A 4"Square Box
B-B 4"Octagonal Box
C-C 3-1/2"Square/Octagonal Box
D-D Masonry Box
E-E 4"Round Box
G-G Single Gang
FIG2
200 Franklin Square Drive,
Somerset, NJ 08873, USA
n MUST conform to the
Hinge
Leveling
Bubble
(+)LINE
(-) COMMON
GROUND
Markham ON, Canada L6C 2S3
Heatsink
Gasket
Base
Plug
Housing
Gasket
FIG3
BLACK
LIGHT
WHITE
FIXTURE