4. Initial setup
1. Affix the stickers enclosed with the tank
documents permanently and firmly to the tank.
A
B
C
Labelling DT-Mobile Easy on both sides
(front and rear)
A
UN 1202 for diesel
Hazard label
B
(flame on red background)
environmentally hazardous
C
substances (tree - fish)
2. Fill the tank (see section 5.4).
Unscrew cap from filling connection a.
The container is filled using a delivery nozzle
with an automatic shut-off.
3. Perform a test filling as described in section 5.5,
but hold the automatic delivery nozzle g in the
still open filling opening a.
4. After completing the test filling, close the filling
opening tight using the cap.
►
The filling station is now ready for operation.
5. Operation
5.1 Storage
Do not expose the DT-Mobil to direct sunlight for
extended periods either during transport or when in
storage. Excessive heating can degrade the quality
of the high-grade plastic container.
If heating produces overpressure in the sealed
container, this overpressure will be released via
the safety valve d .
Important!
i
Do not stack any filled tanks on top
of each other!
Suitable storage conditions:
• ambient temperatures from - 10 °C to + 40 °C.
• level surface.
• canopy for storage outdoors
• Stackability: max. two empty tanks
5.2 Loading the filling station
Risk of injury!
The lid must be closed and completely
locked with the two locks l .
Important!
i
Close ball valve of the delivery line b
GB